User's Manual
The very first time that you apply powewr to the keypad, you will hear a series of beeps followed by
a regular repeating beep (1 beep at 3 second intervals) that lets you know you are in programming
mode:
Enter a 4 digit Master Code that only you will use for programming purposes.
Write Master Code here
You can now add up to 1000 access codes as well as a flash code (for one use only) and a latch
code to hold open the gate.
To add Access Code
1934
To add Access Codes
2413, 888 and 9743
(you may add up to 1000
different codes)
Example - Master Code 1234
Access Code:
Master Code
1 2 3 4 1 9 3 4
Sub Mode Access Code Channel Exit
1 # 1 #
To remove Access Code
1934
Master Code
1 2 3 4 1 9 3 4
Sub Mode Access Code Exit
2 # #
To change Master Code
from 1234 to 4321
Master Code
1 2 3 4 4 3 2 1
Sub Mode New Master Code Exit
7 # #
To clear all Access, Flash
and Latch codes
Master Code
1 2 3 4
Sub Mode
8 #
To add Flash Code 4437
(for one use only)
Master Code
1 2 3 4 4 4 3 7
Sub Mode Flash Code Channel
3 # 1
To set relay output time
15 seconds
(1/2 - 60 seconds)
Master Code
1 2 3 4 1 5 #
Sub Mode # Seconds
5 #
To set relay output time
1/2 second
1 2 3 4
0 # 5 #
Master Code
1 2 3 4 2 4 1 3
Sub Mode Access Code Channel Exit
1 # 2 #
8 8 8 8 3 #
9 7 4 3 4 #
beep -