User's Manual

Table Of Contents
emerald TS100/200/300 Installation Manual
85
Appendix V: Configuring a Third Party Reader
as a Master
It is possible to configure an emerald with a third party read head as a master reader. This
configuration may be used in a system where two card technologies are in use and it is
necessary to have two read head technologies on the same side of a door. An exit request
(REX) switch may be used to control egress via the same door.
Figure 81 Possible system configurations
Hardware installation
For detailed wiring information, please refer to the following sections:
Terminal with 3rd Party Wiegand Read Head on page 20
Terminal with Request to Exit Switch on page 18
Software configuring
1. From the Floatbar open Device Configuration | Devices.
2. Follow the procedure for adding a TS100/TS200/TS300 device as described in Adding the
device to AC2000 on page 38.
Note
In the Configuration tab, ensure that the Door mode is set to Control Post.
Third party
master
reader and
REX