User's Manual
Table Of Contents
- Introduction
- Mounting the Terminal
- Wiring the Terminal
- 3.1 Cabling requirements
- 3.2 The Front Board
- 3.3 The Input/Output Board
- 3.4 Wiring locks
- 3.5 Terminal with Request to Exit Switch
- 3.6 Configuration information
- 3.7 Terminal with 3rd Party Wiegand Read Head
- 3.8 Configuration information
- 3.9 Terminal with S610s Exit Reader
- 3.10 Terminal with DIU 210
- 3.11 Terminal with DIU 230
- 3.12 PoE+ Terminal with S610s Exit Reader
- 3.13 Tamper Detection on Reader Inputs
- Reader Network Configuration
- AC2000 Software Configuration
- The System Configuration Menu
- Door Modes
- Appendix II: Device Settings Remote Application
- Appendix III: Broadcast and Timezone Priorities
- Appendix IV: Loading Card Definitions
- Appendix V: Configuring a Third Party Reader as a Master
TSR-IM-0045-1.6
76
Configuring the options
There are nine options that may be configured via this application. All changes made on the
terminal are saved on the AC2000 server. After changes are made, press the save button.
Lock open time
Lock open time sets the length of time in seconds that the lock power will drop when a valid
card is swiped.
Figure 69 Configuring the lock open time
Door close after
Door close after time sets the length of time in seconds that the door may be held open after a
valid card swipe before a door held alarm is generated.
Figure 70 Configuring the door close after time
Passenger time
Passenger time sets the length of time in minutes that the door may be held open in passenger
mode before a door held alarm is generated.
Figure 71 Configuring the passenger time
Adjust the time in one second
increments by tapping the
plus and minus buttons
Time in seconds
Time in seconds
Adjust the time in one
second increments by
tapping the plus and minus
buttons
Adjust the time in one second
increments by tapping the
plus and minus buttons
Time in seconds