User's Manual
Table Of Contents
- Introduction
- Mounting the Terminal
- Wiring the Terminal
- 3.1 Cabling requirements
- 3.2 The Front Board
- 3.3 The Input/Output Board
- 3.4 Wiring locks
- 3.5 Terminal with Request to Exit Switch
- 3.6 Configuration information
- 3.7 Terminal with 3rd Party Wiegand Read Head
- 3.8 Configuration information
- 3.9 Terminal with S610s Exit Reader
- 3.10 Terminal with DIU 210
- 3.11 Terminal with DIU 230
- 3.12 PoE+ Terminal with S610s Exit Reader
- 3.13 Tamper Detection on Reader Inputs
- Reader Network Configuration
- AC2000 Software Configuration
- The System Configuration Menu
- Door Modes
- Appendix II: Device Settings Remote Application
- Appendix III: Broadcast and Timezone Priorities
- Appendix IV: Loading Card Definitions
- Appendix V: Configuring a Third Party Reader as a Master
A2SE67-UG-0011-1
CHAPTER 7 : Door Modes
58
1. The card is swiped at the terminal and access granted.
2. Lock power is dropped for a period of time known as Lock open time. (Five second
default) If the door is not opened by the end of this time, the lock re-engages.
3. After the door is opened by the cardholder the lock power remains off for a period of time
to prevent the lock re-engaging and closing the door before it is fully opened. This is the
Lock open time 2. (One second default)
4. The door is closed. If the door remains open longer than the Door close after time a door
held alarm will be generated on the terminal and the AC2000 system. (Default 15 seconds)
Configuring the timings in the devices application
1. From the Floatbar open Device Configuration | Devices.
2. Select the terminal from the list and open the Configuration panel.
3. Open the Common panel.
Figure 46 Updating the door cycle timings
Note
Configuration of other timings is covered in the appendices of this manual.
7.1.2 Multi-swipe access
The emerald terminal can be configured to require swipes from up to five valid cards before
granting access. This is configured using the Device application. Once this setting is
Select the
timing which
is to be
amended
Update the
value
required in
seconds
Click Save