User's Manual
Table Of Contents
- Introduction
- Mounting the Terminal
- Wiring the Terminal
- 3.1 Cabling requirements
- 3.2 The Front Board
- 3.3 The Input/Output Board
- 3.4 Wiring locks
- 3.5 Terminal with Request to Exit Switch
- 3.6 Configuration information
- 3.7 Terminal with 3rd Party Wiegand Read Head
- 3.8 Configuration information
- 3.9 Terminal with S610s Exit Reader
- 3.10 Terminal with DIU 210
- 3.11 Terminal with DIU 230
- 3.12 PoE+ Terminal with S610s Exit Reader
- 3.13 Tamper Detection on Reader Inputs
- Reader Network Configuration
- AC2000 Software Configuration
- The System Configuration Menu
- Door Modes
- Appendix II: Device Settings Remote Application
- Appendix III: Broadcast and Timezone Priorities
- Appendix IV: Loading Card Definitions
- Appendix V: Configuring a Third Party Reader as a Master
AC2000 Getting Started Guide
31
3.13.3 Re-assembling the terminal
1. Ensure that there is adequate cable length available to reach the connectors comfortably
for each of the following:
–12vDC
– Cat5e/6 cable for communications and / or PoE
– Output wiring for lock
– Wiring for inputs e.g. door position sensor, lock sense
Important
To maintain the terminal’s IP65 rating, the cable access hole should be adequately sealed before completing the
installation process.
2. Attach the front pane of the terminal via the ribbon connector.
3. Attach the front of the terminal to the back casing and fix in places with the screws.
4. Attach the protective side panels to the terminal.
Note
If the terminal needs to be open after installation, the side panels can be removed by inserting
a 5 mm flat head screwdriver into the slot under the centre of the panel and sliding along the
length of the panel.