User's Manual
Table Of Contents
- Introduction
- Mounting the Terminal
- Wiring the Terminal
- 3.1 Cabling requirements
- 3.2 The front board
- 3.3 The input/output board
- 3.4 Wiring locks
- 3.5 Terminal with Request to Exit switch
- 3.6 Configuration information
- 3.7 Terminal with third-party OSDPv2 read head
- 3.8 Terminal with third-party Wiegand read head
- 3.9 Terminal with DIU 230 and third-party Wiegand read head
- 3.10 Configuration information
- 3.11 S700e with S700s exit reader
- 3.12 S700 with DIU 210 and S700s exit reader
- 3.13 S700 terminal with DIU 230
- 3.14 Tamper detection on reader inputs
- Reader Network Configuration
- AC2000 Software Configuration
- The System Configuration Menu
- S700 Operational Modes
- Appendix 1 Updating Firmware
- Appendix 2 Broadcast and Timezone Priorities
- Appendix 3 Loading card definitions
S700-IM-0088-1.72
CHAPTER 5 : AC2000 Software Configuration
60
5.3.5 Deleting a device input
To delete a device input, complete the following steps:
1. Select the input from the Device Inputs list.
2. Click Delete.
3. From the window that appears, click Delete to delete the device from the system or
Cancel to cancel the process.
Note: Care should be taken when deleting an input as no warning message appears.
5.3.6 Input alarms
The following input tables describe the set-up for each of the S700 configurations outlined in
this manual, including the AC2000 alarms that must be selected for each sensor state where
appropriate:
Input table for S700 with REX and S700 with third-party read head:
Input number Input function Sensor state AED alarm
0 Door position Open Door forced
Closed Door closed
1 Lock position Open Lock not engaged
Closed Lock engaged
2 Request to exit No default
3 Spare / interlock No default
Table 22: S700 and REX / Third-party read head input alarms