11.1 Check List/Commissioning Sheet
TBA
11.2 S400 Exit Reader Connections
IMPORTANT: Ensure that J11 JUMPER 7 (do not confuse with LK7) is fitted on the S400 exit
reader for use with the S600E master reader.
The S400 exit reader is connected to the master reader through an RS485 port. The connection is
made from connector J5 on the master reader PCB to connector J16 on the exit reader (as above)
and terminated at both ends by way of a 4-way JST socket.
Note: the S400 exit reader differs from the S610S in that it does not contain any RAM, RAM
backup battery or clock chip.
Connector J5 on S610S is connected to J16 on the S400 exit reader.
11.3 CLK Air Bridge
CLK has used AC3000 system with DAC and S400 card readers to secure the Air-Bridge facility
and AC2000 system containing S610E and S610S card readers will replace AC3000 system. CLK
has requested new feature of Passenger mode to be implemented to card readers. To satisfy this new
door mode called “Passenger-Staff exit” has been created.
PASSENGER-STAFF EXIT MODE
Passenger-staff exit is the newly created door mode to support AC2000 system to be used to secure
the CLK Air-Bridge facility. This mode is mainly based on “Passenger Mode” and includes the
new features requested from CLK.
12v GND
Data
A
Data
B