User's Manual

Table Of Contents
S610S Manual - Hardware Installer Manual - Version 1.8
53
10.7 Adjusting optical Tamper Thresholds
Firmware revision B1.00.018 onwards.
This allows the installer to set a low and high threshold for tamper.
The lower threshold (set in the Tamper Low menu) should be set
while the unit is mounted properly on its case or enclosure.
The upper threshold should be set so that it doesn’t trigger while on the case.
In the setup menus enter,
Configure -> Local settings -> Tamper Values
TAMPER LOW
The LCD will show:
The number in the brackets is the current light level being monitored. The brighter the ambient
conditions the higher the number.
Cur shows the current value the sensor is configured too.
Xxx is the field where the new value ca be entered. A leading 0 is necessary if only two digits are to
be entered e.g. to enter a value of 8 press 008 then to OK.
The low tamper value is the normal light conditions in the closed case used to reset the sensor after
it has been triggered.
TAMPER HIGH
The LCD will show:
The number in the brackets is the current light level being monitored. The brighter the ambient
conditions the higher the number.
Cur shows the current value the sensor is configured too.
Xxx is the field where the new value can be entered. A leading 0 is necessary if only two digits are
to be entered e.g. to enter a value of 8 press 008 then to OK.
The high tamper value is the amount of light needed to trigger a tamper alarm. This can be
compared to the value in the brackets which is a snapshot of the light level when the Tamper High
config is selected.
10.8 Disable diagnostic mode pin
On and AC2000 workstation using the Devices application, select a configured S610S reader, select
Configuration, from the Device Configuration table select Element Diagnostic PIN as shown below.
Click on the
Edit button and set the value to -1. This will disable any access to diagnostic mode
from the reader. If an S610S has the value10000 change this to -1 to keep diagnostic mode
disabled, or to another value to enable diagnostic mode.
10.9 Updating Firmware
Firmware upgrades, or defrosting, can be carried out in different ways depending on the software
you are using and the operational constraints existing on your system.
Normally the AC2000 web configuration tool is used to download a firmware update to a selected
S600E reader. The reader must already be configured using the AC2000 workstation Devices
application, and must be online to receive the new firmware.
AC000 web configuration tool
You will be prompted for a User name and Password, the User must have Authorisation Level 4.
Ensure you have the upgrade *.dat file available.