User's Manual

Table Of Contents
S610S Manual - Hardware Installer Manual - Version 1.8
50
10.3 Information Menu
Use this menu to easily read the IP address, MAC address, RTC and Web addresses the reader is
using.
Network
RDR address -
entered by an installer using the Diagnostic Keypad. The third digit from the right is
the actual address of the reader, B in the example below.
The address of the reader in the example above is B
Versions
Software Type - Indicates the reader type, determined by the firmware, e.g. S610S
Software version - Firmware version, currently, B1.00.041
Software date - Release date of the firmware currently installed on the reader
Hardware version - Version of reader hardware as at manufacturing
HW serial No - Hardware serial number
Database
DB Format - 3 & 4 byte indicated only card numbers are held in the reader’s Off Line database, “8
byteindicates the Card Number, Timezone, status and PIN are all held in the readers Off Line
database.
DB free space - 223424
Cards - Number of card details held in Off Line database
Transactions - Number of transactions held in Off Line database
Last Configuration time - “Not configured” means that the reader has not yet successfully received a
configuration from the controller, other wise the time of the last configuration from the controller is
displayed.
Timezones - PZ - CZ - OZ
SMART Keys - No KEYS Loaded
System
DIU - yes/no
Exit Reader - active/inactive
Door Mode - current mode of reader is reported
Local Keypad - enabled/disabled
Exit Keypad - enabled/disabled
Relay State - reports current state of master and Exit reader relays, 0, 1, 2, 3.
2
nd
Relay Action - not supported
Sounder Action - Sounder enabled/Disabled
Diagnostic card - enabled/disabled. Installers can use special cards which allow direct access to the
diagnostic mode. Normally disabled.
Card Format - current card Format read by readhead is reported
Tamper values - High and Low tamper values reported
Prox Head - shows Prox Head ON or Off, and whether SmartHead enabled/disabled.