User's Manual

Table Of Contents
S610S Manual - Hardware Installer Manual - Version 1.8
40
If no feedback signal is provided from the external equipment the inputs must be disabled,
otherwise the reader will wait for a response before continuing. In the S610S will disable the
amber LED on the master and slave head, disable relay0 (relay1) and transmit a Equipment
Disabled signal to the host controller. If the S610S is not online to the host controller, all the above
alarms are stored as offline transactions.
Automatic equipment disable feature
The external equipment can be automatically disabled after a configurable period. This timeout is
initialised every time the piece of equipment is enabled. An automatic disable will occur if the piece
of external equipment is not disabled before the timeout expires. Whenever this timeout occurs, a
card usage packet will be transmitted to the host controller (the card number used to enable the
equipment will be in the packet) and the S610S will perform the functions outlined in “S610S in
EQUIPMENT ENABLED state above. The timeout period is set by
LockOpenTime2. If pulsed
operation is needed i.e.,
LockOpenTime2 =0, then the timeout period is set by the configurable
parameter
OccupancySwipeTime (seconds).
If the S610S is offline (whenever the timeout occurs) an offline transaction with outcome code hex
1E is stored for later transmission to the host controller.
Equipment Enable - Time settings
LockOpenTime (Secs) time output relay is initially pulsed
LockOpenTime2 (Mins) – time output relay is held in the enabled state
I/P-MAP0 – used to enable input monitoring for equipment enabled for swipes originating on
master head. Input0 must be disabled if not used.
I/P-MAP2 – used to enable input monitoring for equipment enabled for swipes originating on slave
head. Input2 must be disabled if not used.
OccupancySwipeTime (Mins) automatic equipment disable period (if LockOpenTime2 =0)
DOOR-MODE (type) – value of 09 configures reader as Equipment Enable Mode
Timed Output sequence of S610S reader in Equipment Mode
Equipment type A – One second Pulse each for start and stop, either side of LockOpenTime2
Equipment type B Relay output changes state for duration of cycle, Occupancy time.
Equipment Enable card usage outcome codes
Outcome Code Event
Hex 1C Equipment Enabled
Hex 1E Automatic Equipment Disabled
Hex 1D Equipment Disabled
Lock Open Time
(Secs)
Lock OpenTime2 (Mins)
Card Swipe
END OF CYCLE
Lock Open Time
(Secs)
Equipment Mode Only - Type A
A
RELAY ACTIVE
Lock Open Time
(Secs)
Occupancy Time (Mins)
Card Swipe
END OF CYCLE
Lock Open Time
(Secs)
Equipment Mode Only - Type B
B