Configure in AC2000 Devices application if an Alarm is required.
IP1 Input Used to record Turnstile position after Readhead1 cardswipe
Configure in AC2000 Devices application if an Alarm is required
IP2 Input REX Button (Head0 side of Turnstile, triggers Relay0)
(Optional)
IP3 Input REX Button (Head1 side of Turnstile, triggers Relay1)
(Optional)
Relay0
Output Dry contact relay. Note the Relay changes state on reader power up.
Choice of Normally Open or Normally Closed contacts.
Release signal to Turnstile for Direction0
Actioned by a valid cardswipe on Readhead0
Relay1
Output Dry contact relay. Note the Relay changes state on reader power up..
Choice of Normally Open or Normally Closed contacts.
Release signal to Turnstile for Direction1
Actioned by a valid cardswipe on Readhead1