S610S Manual - Hardware Installer Manual - Version 1.8
34
IDLE STATE
In the idle state all doors are closed and locked and the Air-Bridge lobby is secured. The Air-
Bridge lobby may change to either passenger access or staff access from the idle state.
STAFF ACCESS
Staff Access feature is designed to allow single person access. When reader is in the idle state, the
normal card swipe de-energises electro-magnetic door lock for door open time while the special
usage card swipe de-energises door lock for extended door open time.
These door open times are configurable.
PASSENGER ACCESS
When a special usage card is swiped during Passenger Access mode active, the option to either
Cancel or Restart the Passenger Access mode will be given. Cancelling the mode will energise
electro-magnetic door lock and make reader ready to generate the door open alarm displaying
“CLOSE DOOR !!” message on LCD. If door is not closed for a configured time, Reader will
generate the door open alarm.
Restarting the mode will re-initialise and extend the mode for the extended door open time.
REX
Using a REX which interrupts the Passenger Access mode will cancel the mode.
When Reader is in the idle state and Door mode is Standard Passenger Mode, REX will start the
Passenger Access mode de-energising door lock for the extended door open time.
When Reader is in the idle state and Door mode is Passenger-staff exit Mode, REX will work as per
a normal card swipe (door open time).
Second Swipe Action configuration
Second Swipe Action contains three special options to define the action of the card swipe during
the Passenger Access mode is ON. Note that Second Swipe Action is basically designed for a
special usage card swipe. In some cases, however, a normal card swipe will get the same effect.
RE-ENABLE MODE
Re-enable mode = 0x00
This is the default value of Second swipe action configuration.
Special usage card swipe:
When a special usage card is swiped during the Passenger Access mode, The reader displays Mode
Extension Menu [ End * Restart # ] and this will allow card holder to either Cancel or Restart the
mode.
The second card swipe doesn’t affect the Passenger Access mode until one of options is selected
and the mode is still on process counting down timer even though
Mode Extension Menu is being
displayed on the LCD.
The diagram below shows a process sequence when Restart is selected.
First Card swipe
Second card
swipe
Restart Selected Door Close
Mode
Passenger Access Mode
New Passenger Access Mode
Door open time
Door open time