4.1 S610S Master Reader 12V Power and Data connections
Shows S610S, RS485data, power and Exit Reader connections.
If Exit Reader present; check required Slave reader settings in Devices configuration.
If an S400 Exit reader is present ensure S400 PCB J11 jumper 7 is ON. (Do not confuse with LK7)
Setting the Master S610S Exit reader configuration
Wire an Exit reader to the master as shown above.
A Master serial reader does not automatically connect to the Exit Reader or DIU after receiving
its configuration, set by using the AC2000 workstation Devices Application.
The installer must also set the reader to communicate with the Exit Reader DIU using the reader’s
onboard keypad.
REQUIRED SETTINGS MADE AT THE MASTER READER
On the master reader, use the key to navigate to the Configuration menu.
Press key, then the key to navigate to the AUX Device(s) menu
Select EXIT READER or NO EXIT READER accordingly.
After the setting has been accepted, press repeatedly until the reader exits diagnostic mode.
Do the same for a DIU if present.
For more information on using the reader’s Diagnostic mode S610S onboard diagnostic mode see
Chapter 10 in this manual.