User's Manual
Table Of Contents
- Important Safety Information
- Introduction
- Getting Started
- InfoProx Hardware Installation
- Configuring the Door Control Unit
- First Time Access to the Administration Menu
- Accessing the Administration Menu after Password Setup
- Getting to know the configuration setup
- Configuring the reader
- Configure Current Time
- Configure Time Zone
- Time zone types
- Configure Inputs
- Doorstrike Time
- Door Close After Time
- GIN Configuration
- Site Code
- Door Control Unit Diagnostic Screen Set Up
- Contrast
- Door Mode
- Keypad Enable / Disable
- Exit Configuration
- Relay Idle State
- Card Management
- DIAGNOSTIC ROUTINE
- InfoProx Technical Description
- Glossary
InfoProx Entry Technical Description
The following illustrates the door reader wiring requirements.
J2
+
-
Lock
1098765432 1
PSU
Input_0
Door
Position
(N/C)
Input_1
Lock
Status
(N/C)
Input_2
Push
Button
(N/O)
Input_3
Spare
(N/C)
Figure 11: Door reader wiring
Functional Checks
Use the diagnostic routine to check the inputs to the reader. Input 0 (door position)
and input 1 (lock status) should be ON when the door and lock are closed; these
inputs should be OFF when the door and lock are open. Input 2 should not be ON
unless the push button is pressed.
Control Post Reader
1 Master reader
Application for the Reader
The Control Post reader is designed for use at a manned location, where there is
no physical barrier. None of the inputs are reserved and a valid card swipe does
not fire a relay. The purpose of this mode is to record whether or not a person has
passed this point, providing data for a transaction report.
Functional Checks
Use the diagnostic routine to test the inputs to the reader. When in Control Post
mode, the reader’s four inputs are non-assigned and can be configured as
"normally on" or "normally off," depending on what the input is monitoring. A
diagnostic swipe will show the current state of these inputs.
Technical Support
If you have post-sale technical problems operating the InfoProx Entry Reader or
Software Utility program, contact your dealer. Software House provides a
Customer Support Center, Monday through Friday from 8:00 am to 8:00 pm,
Eastern Standard Time: 1-781-890-2287 or 1-800-392-2873.
Before calling, please check your manual and make sure that the unit is setup and
powered properly. If you still need to call, have the following information available:
Software House 67