User's Manual

Table Of Contents
Diagnostic Routine InfoProx Entry
n Timezone setup:
Diagnostic Tests
PIN Only
In this example, a PIN Only Timezone is configured.
n LED testing sequence:
Diagnostic Tests
Red Led 0
Diagnostic Tests
Green Led 0
Diagnostic Tests
Amber Led 0
n Keypad testing:
Diagnostic Tests
Key Pressed =
Press every key on the reader to test its functionality. If working, the key
displays on the screen.
n Testing the read head:
Badge Exit Head
n Testing the four reader inputs, showing status as open, or closed:
I/P No.0123
ssnn
The example given above indicates that inputs 0 and 1 are Closed (ss)
(s=shorted) for this reader, while input 2 is Open (n) and input 3 is
Normal (n = open circuit mode).
To hold the diagnostic test on the inputs’ check, press #. An H displays
to the right of the input settings. By opening and closing the door, switch
the inputs between OPEN and CLOSED to check that the reader is
monitoring them properly.
1. Press # again to leave the inputs check and continue the diagnostic
routine:
Once the diagnostic checks have been completed, the reader displays
the screen below before returning to the normal idle display:
4-Diag, 5-Pword
6-Backup,
58 Software House