User's Manual

Table Of Contents
EtherProx Entry Administering EtherProx Entry
displayed, too. Hours and minutes are shown in the 24-hour format. The colon
flashes on the seconds digit.
Note If the –S sequence appears, check your RJ45 connection and make
sure that all connections are tight.
After a valid card swipe, the LCD displays a message, as shown in the following
example:
Access granted
Show card 16:31
When a door override or similar operation is active, the following LCD display
appears:
EtherProx Rdr E
Door open 16:35
The status and error messages and their meanings are listed in the three tables
that follow: When a card is presented, one of the following responses is
generated:
LCD message LED Comment
Access Granted
Green Card valid for access
Card Error RETRY
Red Problem reading card
Card Expired
Red
Card not operational but is in
system.
Lost/Stolen Card
Flashing
Red
No access allowed
No Database!
Red
No access; no cards in
system.
Not In System
Red Card number not known
PIN Timed Out
Amber
Requested PIN entered too
late
Wrong PIN,Retry
Amber
Invalid card and PIN
combination entered
Wrong Timezone
Amber
Card cannot be used at this
time
Software House Page 41