User's Manual

Table Of Contents
Administering EtherProx Entry EtherProx Entry
Configure Door
The following table lists the Configure Door settings with their descriptions.
CONFIGURE DOOR SETTING DESCRIPTION
Unlock Time Length of time that the lock is released
Relock Delay Time Number of seconds to delay the relock
after a door is detected as open. You must
enable Door Sensing for this setting to
work.
Standard Door Open Time Length of time a door can be open before
an alarm is generated. You must enable
the Door Sensing for this setting to work.
Extended Door Open Time Length of time a special status card can
hold a door open before an alarm is
generated. You must enable the Door
Sensing for this setting to work.
Door Held Warning Length of time a door held warning sound
is generated on the reader before the
alarm goes off. You must enable the Door
Sensing for this setting to work.
Alarm Sounder Duration Length of time a door held open alarm or
door forced open alarm warning is
generated. You must enable the Door
Sensing for this setting to work.
Powered to Secure Specifies whether power to the lock
secures the door (default).
Powered to Unlock Specifies whether power to the lock
unlocks the door.
Door Sensing Enabled Specifies whether a door state switch is
connected. If you disable this setting, the
Standard Door Open Time, Re-lock Delay
Time, Extended Door Open Time, Door
Held Warning, and Alarm Sounder
Duration settings will be disabled.
Lock Sensing Enabled Specifies whether a lock status switch is
connected.
Request to Exit Enabled Specifies whether an exit pushbutton
switch is connected.
Page 36 Software House