EtherProx Entry Introduction
PROX READER UNIT SPASS CODE
InfoProx Entry IPE
InfoProx Exit IPX
InfoProx Online IPO
EtherProx Entry EPE
Note You can use the InfoProx Entry and EtherProx Entry only as entry
readers; you cannot use an entry reader as an exit reader for another
entry reader.
Preparing to Install EtherProx
There are several ways to install an EtherProx reader. You can use an optional Door
Interface Unit (DIU) or reverse the Entry and Exit readers in order to comply with UL 294.
A DIU is an option that provides power for the readers and additional inputs, outputs, and
alarms. You can wire the door controls to the DIU, making the installation UL 294-
compliant.
If you install readers for only inside access control and not for outside access control, your
installation does not have to comply UL 294 requirements.
When you install the Entry reader on the secure side of the
door, the wiring is not accessible during an attempted
break-in. With this type of installation, the Transaction report
will show an entrance as Access granted - Exit and an exit
as Access granted – Entry.