Instruction manual
Centre of door
Step 
Ladder
Step 
Ladder
C rail
Door
Highest point  
of door travel
Fig. 19
Fig. 18
Fig. 17
Fig. 20
Mounting on a Non-Track Type Door
WARNING: Make sure concrete, brick wall or 
timber lintels are solid and sound so as to form 
a secure mounting platform. 
Step 9 - Determine the Door’s Centre
Find the centre of the door and mark this location both a. 
above the door and on top of the door. 
Draw two lines 21.5mm either side of this b.  (Fig. 17).
Step 10 - Prepositioning the Opener
Raise the door to open position.a. 
Rest the opener on the top edge of the door with end b. 
of the C-Rail against the wall (Fig. 18).
Support the powerhead level  with the  lowest point of c. 
the open door (Fig. 18).
NOTE: Do not slide C-Rail along the face of the door.
Step 11 - Mounting the C-Rail
Close the  door slowly. The  C-Rail will  be elevated  by a. 
the top edge of the door as it moves. 
Stop the door when it is at its highest point of travel.  b. 
Allow 25mm additional  height for clearance between 
the door and the track (Fig. 19).
Support the C-Rail in this position and close the doorc. 
The height determined in Step 11(b) will be the height d. 
at which to mount the wall bracket.
Centre the bracket along the line determined in Step 9.e. 
Using  the  bracket  as  a  template,  mark  a  minimum f. 
of two holes and drill with appropriate size bit.  For a 
more secure fitting, the wall bracket can be anchored 
using more than two holes.
Secure the bracket to the wall using: g. 
IF CONCRETE OR BRICK - 10mm dynabolts. 
IF TIMBER - wood screw #20 or equivalent   
   (minimum 50mm long).
Attach the  wall bracket to  the C-Rail  with the 90mm h. 
long clevis pin (Fig. 20) and secure by a snap pin.
Step 12 - Securing the Powerhead to the Ceiling
Secure  the  perforated  angle (not  supplied)  to the a. 
ceiling above where powerhead’s mounting holes will 
be. See (Fig. 16) for a representative mounting.
Connect  the  powerhead  to  the  ceiling  mounted b. 
perforated angle  with M8x20mm  screws and  nuts. 
Strips should  not extend  more than  18mm below 
centre of powerhead mounting holes (Fig. 16).
WARNING: The opener must be securely 
fastened to structural supports, otherwise 
opener failure may ensue causing serious 
personal injury and/or property damage.
Controll-A-Door
®
 P
Diamond Instruction Manual14