User's Manual

33
Important: Using this product in any manner other than
outlined in this document voids your warranty. Also,
Control4 is not responsible or otherwise liable in any
way for any damage resulting from the misuse of this
product. See
ctrl4.co/warranty
for details.
Specifications
Model number
C4-Z2IO
System requirements
Control4 OS system
requirements
OS version 2.10.0 or greater
Control4 system
integration
Each installed ZigBee IO and Extender adds sensor
and input connections to the Composer project.
Driver
The ZigBee IO and Extender (C4-Z2IO) is available
in the Composer Online Driver Database.
Communication
Networks supported
Control4 ZigBee Pro mesh networking protocol,
based on the IEEE 802.15.4 ZigBee standard
ZigBee data rate
250 kbps
ZigBee frequency
range
2.405 – 2.475 GHz
Connections
Contact sensor input
4 inputs, accepts AWG 16-28, common ground
connection.
Relay terminal ratings
0.5A @ 50V, 1A @ 24V or less
Max voltage: TBD
External thermistor
1 thermistor input, sold separately.
See “Accessories”
Infrared
2 3.5 mm IR ports
Integrated features
Internal contact
Internal magnetic reed switch
Requires external magnet, sold separately
Integrated internal
thermistor
Internal thermistor can be used for local
temperature sensing: 32°F to 104°F (0°C to 40°C)
Integrated humidistat
Can measure local humidity from 5% to 90%.
Power
Power consumption
100mA at 12V, fully active
External low-voltage
power supply
Micro USB power supply (included)
AC/DC 5-24V (optional)
Other
Available colors
Black (water-based paintable enclosure)
Dimensions (L × W × H)
3.1” (78.7 mm) × 2.6” (65.7 mm) × 1.05” (26.6 mm)
Weight
2.5 oz. (70.9 grams)
Environmental
Temperature:
Operational 32°F to 104°F (0°C to 40°C)
Storage -20°F to 158°F (-29°C to 70°C)
Humidity 5% to 95% non-condensing
This device is not waterproof and must be kept out
of direct contact with water. The product must not
be immersed.
Paintable enclosure
The cover assembly plastics are paintable with any
water-based residential paints. Do not clog the
cover assembly vent holes with paint.
Accessories
External thermistor
ZCA-EXT10A, AC-DOTS1-W, AC-PMT51-W
Installing
1 Place the device in a location which ensures the following:
Easy access to any externally-connected wires
ZigBee mesh networking eciency
Note: Make sure the device has good ZigBee wireless
reception by (1) ensuring it is within range of another
ZigBee device and (2) avoiding other electrical
equipment that may cause interference with the ZigBee
signal (such as cordless telephones that operate on the
2.4 GHz frequency.)
Avoiding unnecessary exposure to extreme environmental
conditions.
IMPORTANT! Do not place the device in direct sunlight.
2 If an external thermistor is used with the device, place
it away from direct sunlight, drafts, doorways, skylights,
windows, and exterior walls for best accuracy.
3 Detach the tray from the cover by inserting a flat screwdriver
into the opening slot in the side of the cover and pushing in
gently, while at the same time pulling the cover out and away
from the tray.
Temperature chamber/LED display
Reed switch location
Opening slot
Cover
Tray
The cover holds the radio logic board
(the actual device) and pins, the IR
ports, the internal contact, and the
USB power connector. The cover
attaches to the tray. The tray holds the
wiring terminals and is mounted to a
wall or flat surface.
The cover “rocks” into contact with
the tray. To separate the two, insert a
screwdriver or other flat object into the
opening slot on the side of the cover,
gently push in and then “rock” it away
from the tray.
4 Position the tray against the wall or other flat surface.
5 If you are using the internal contact, position the device so
that the narrow indentation that marks the internal contact
(on the long edge of the cover) aligns with the external
magnet (not included).
B
B
B
B
Indentation
6 Mark the locations of the four screw holes on the wall.
7 If mounting the device to drywall, remove the tray from the
wall and drill four 3/16-inch (4.75mm) mounting holes at the
four screw hole locations (B) previously marked on the wall.