User's Manual
28 29
Setup and testing
Humidifier system settings table
Note: A humidifier can be installed only if ventilation is not installed and Dehumidifier Control is not set to 
Whole Home.
System setting Description
Factory default setting 
(bold) and setting range
Reminder Month 
(Change Water Panel 
Reminder set to 1 Per 
Season) 
First Reminder Month 
(Change Water Panel 
Reminder set to 2 Per 
Season)
If Change Water Panel Reminder is set to 1 Per 
Season: Determines the month the “Change 
Water Panel” message is displayed. 
If Change Water Panel Reminder is set to 2 Per 
Season: Determines the first month the “Change 
Water Panel” message is displayed.
October
November
December
January
February
March
April
May
June
July
August
September
Second Reminder 
Start Month
Determines the second month the “Change 
Water Panel” message is displayed. (Only 
available when Change Water Panel Reminder 
set to 2 Per Season.)
October
November
December
January
February
March
April
May
June
July
August
September
Dehumidifier system settings table
Note: Dehumidifier Control can only be set to Whole Home if ventilation and humidification are not installed.
System setting Description
Factory default setting 
(bold) and setting range
Dehumidifier Control Selects method of dehumidification. (If set 
to None, no other dehumidifier settings are 
available.)
None (no dehumidification 
installed)
Whole Home
Air Conditioner
Humidity Setpoint 
Deadband
Select the minimum dierence between the 
humidifier and dehumidifier setpoints. (Only 
available if Humidifier Mode is set to Manual and 
Dehumidifier Control is set to Air Conditioner. 
Available in both setups.)
10 Percent RH
10 to 20 Percent RH
Lockout Dehumidifier 
During Cooling 
Selects if dehumidification is disabled during 
a cooling call. (Only available if Dehumidifier 
Control is set to Whole Home.)
No
Yes
Dehumidifier Forces 
Fan
Selects if dehumidification can turn on the fan. 
(Only available if Dehumidifier Control is set to 
Whole Home.)
No
Yes
Dehumidifier Service 
Reminder
The period for displaying the “Dehum Service 
Reminder” message. (Only available if 
Dehumidifier Control is set to Whole Home.)
O
1 to 12 months or “O” to 
disable
Dehumidifier 
Overcooling Limit
Selects the amount of overcooling that can 
occur for dehumidification. (Only available if 
Dehumidifier Control is set to Air Conditioner.)
3°F (1.5°C)
1°F to 3°F (0.5°C to 1.5°C) 