User's Manual
28 29
Setup and testing
Humidifier system settings table
Note: A humidifier can be installed only if ventilation is not installed and Dehumidifier Control is not set to
Whole Home.
System setting Description
Factory default setting
(bold) and setting range
Reminder Month
(Change Water Panel
Reminder set to 1 Per
Season)
First Reminder Month
(Change Water Panel
Reminder set to 2 Per
Season)
If Change Water Panel Reminder is set to 1 Per
Season: Determines the month the “Change
Water Panel” message is displayed.
If Change Water Panel Reminder is set to 2 Per
Season: Determines the first month the “Change
Water Panel” message is displayed.
October
November
December
January
February
March
April
May
June
July
August
September
Second Reminder
Start Month
Determines the second month the “Change
Water Panel” message is displayed. (Only
available when Change Water Panel Reminder
set to 2 Per Season.)
October
November
December
January
February
March
April
May
June
July
August
September
Dehumidifier system settings table
Note: Dehumidifier Control can only be set to Whole Home if ventilation and humidification are not installed.
System setting Description
Factory default setting
(bold) and setting range
Dehumidifier Control Selects method of dehumidification. (If set
to None, no other dehumidifier settings are
available.)
None (no dehumidification
installed)
Whole Home
Air Conditioner
Humidity Setpoint
Deadband
Select the minimum dierence between the
humidifier and dehumidifier setpoints. (Only
available if Humidifier Mode is set to Manual and
Dehumidifier Control is set to Air Conditioner.
Available in both setups.)
10 Percent RH
10 to 20 Percent RH
Lockout Dehumidifier
During Cooling
Selects if dehumidification is disabled during
a cooling call. (Only available if Dehumidifier
Control is set to Whole Home.)
No
Yes
Dehumidifier Forces
Fan
Selects if dehumidification can turn on the fan.
(Only available if Dehumidifier Control is set to
Whole Home.)
No
Yes
Dehumidifier Service
Reminder
The period for displaying the “Dehum Service
Reminder” message. (Only available if
Dehumidifier Control is set to Whole Home.)
O
1 to 12 months or “O” to
disable
Dehumidifier
Overcooling Limit
Selects the amount of overcooling that can
occur for dehumidification. (Only available if
Dehumidifier Control is set to Air Conditioner.)
3°F (1.5°C)
1°F to 3°F (0.5°C to 1.5°C)