Thermostat with Humidity or Ventilation Control User Guide ™ ™
Disclaimer Control4® makes no representations or warranties with respect to any Control4 hardware, software, or the contents or use of this publication, and specifically disclaims any express or implied warranties of merchantability or fitness for any particular purpose. Control4 reserves the right to make changes to any and all parts of Control4 hardware, software, and this publication at any time, without any obligation to notify any person or entity of such changes. Trademarks ©2014 Control4.
Contents About your new thermostat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Supported model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Important safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Thermostat features. . .
Quick reference to controls and display Control4 thermostat with humidity or ventilation control User guide Supported model Thermostat features C4-THERM-WH • • Thermostat—White Important safety instructions Warning! Install in accordance with all national and local electrical codes. Warning! This product is not intended for use with line-voltage baseboard heaters. Important: Improper use or installation can cause loss/damage of property.
Operation Operation Select fan setting (On/Auto/Circ) Select system mode (Em Heat/Heat/Off/Cool/Auto) When the fan mode is changed during a program event it remains in that mode until the next event starts. The fan must be programmed to FAN ON in the schedule to run continuously through all events. Press button to select: button to select: Em Heat: (only for heat pumps with auxiliary heat) Thermostat controls auxiliary heat. Heat pump will not operate in Em Heat mode.
Indoor Air Quality functions Power and battery replacement Humidifier control This thermostat can be AC powered, battery powered, or both (to provide backup power for communication with the Control4 system). The thermostat uses four alkaline AA batteries. If humidification is installed it can be controlled in two modes, automatic or manual. The thermostat has a memory backup that saves the thermostat settings in case of a power interruption.
Indoor Air Quality functions In manual mode it is important to anticipate a drop in outdoor temperature and reduce the setting accordingly to avoid excessive condensation. Use the following table to determine the proper relative humidity setting.
Program schedule and holds Fresh Air Program schedule and holds If ventilation is installed, Fresh Air can operate in four different modes as defined on this page. Understanding program schedules Press screen. button to select Fresh Air and enter the Fresh Air Setting the schedule for the thermostat is done at the Control4 system.
Program schedule and holds Next Event hold Press or buttons to immediately adjust the temperature when the schedule is running. This will hold the temperature setting until the next scheduled event. A Next Event hold can also be initiated by pressing selecting Next Event. Timed hold Timed hold can be set at the Control4 System.
™ ™ control4.com | 888.400.4070 90-1883 3.
Thermostat with Humidity or Ventilation Control Safety and Installation Instructions
Disclaimer Control4® makes no representations or warranties with respect to any Control4 hardware, software, or the contents or use of this publication, and specifically disclaims any express or implied warranties of merchantability or fitness for any particular purpose. Control4 reserves the right to make changes to any and all parts of Control4 hardware, software, and this publication at any time, without any obligation to notify any person or entity of such changes. Trademarks ©2014 Control4.
iv Supported model Setup and testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Equipment Type selection switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Installer Setup menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General description Box contents General description Box contents Supported systems This Control4® Thermostat enables intelligent HVAC and Indoor Air Quality control as part of a Control4 automated system. This thermostat uses the ZigBee® (802.15.4) wireless networking standard to communicate with the Control4 system.
Installation Installation Installation location recommendations If replacing an existing thermostat Thermostat should be mounted: • • • • • On an interior wall, in a frequently occupied space. Approximately 5' (about 1.5 meters) above the floor. At least 18" (about 0.5 meter) from an outside wall. Thermostat can be mounted to a vertical, single gang, electrical junction box. Do not mount thermostat: • • • • • 4 Behind doors, in corners, or other dead air spaces.
Installation Thermostat mounting 1 Remove the rear mounting plate from the thermostat. 2 Pull wires through the opening on the back of the thermostat. 3 Position and level the mounting plate of the thermostat on the wall, and mark the hole locations with a pencil. 4 Drill 1/4" (6.35 mm) holes and insert the supplied anchors (drywall only). 5 Place the mounting plate over the anchors, then insert and tighten the screws.
Installation Outdoor temperature sensor (included) I1 & I2—Indoor Air Quality control output C—Common (optional when powered by batteries) O/B—Reversing valve Y—First-stage cooling / compressor Heat pump models can use the outdoor temperature to effectively utilize the heat pump: Y2—Second-stage cooling / compressor • G—Fan RC—24VAC supply cooling1 R—24VAC supply heating1 W2—Second-stage heat / auxiliary W—First-stage heat / auxiliary L—System fault indicator (optional) (heat pump only) S1 & S2—Outdoor
Installation Remote temperature sensor (optional) The outdoor temperature sensor should be mounted: RC R C L Y G O/B W • RC R C L Y G O/B W • • • • 10 On the side of the building out of direct sunlight (north side recommended). Above snow line. At least 3' (about 1 meter) away from exhaust vents and condensing lines. Using less than 300' (about 100 meters) of wire. Do not route wires parallel to 120VAC lines.
Installation Conventional heat/cool wiring diagrams 12 Y G O/B W RC R C L Y G O/B W RC R C L Y G O/B W RC R C L Y G O/B W S1 S2 T1 T2 I1 I2 W2 Y2 S1 S2 T1 T2 I1 I2 W2 Y2 S1 S2 T1 T2 I1 I2 W2 Y2 REMOTE TEMP SENSOR (OPTIONAL) S1 S2 T1 T2 I1 I2 W2 Y2 2nd HEATING 1st HEATING RC R C L 2nd COOLING FAN 1st COOLING TRANSFORMERS 2nd HEATING 2nd COOLING FAN 1st HEATING Two transformers (remove jumper wire) OUTDOOR TEMP SENSOR (OPTIONAL) Behind doors, in corners, or other dead air spaces.
Installation RC R C L Y G O/B W RC R C L Y G O/B W RC R C L Y G O/B W REMOTE TEMP SENSOR (OPTIONAL) S1 S2 T1 T2 I1 I2 W2 Y2 OUTDOOR TEMP SENSOR (OPTIONAL) S1 S2 T1 T2 I1 I2 W2 Y2 REMOTE TEMP SENSOR (OPTIONAL) S1 S2 T1 T2 I1 I2 W2 Y2 OUTDOOR TEMP SENSOR (OPTIONAL) S1 S2 T1 T2 I1 I2 W2 Y2 Dehumidifier wiring Humidifier wiring RC R C L Y G O/B W RC R C L Y G O/B W RC R C L Y G O/B W RC R C L Y G O/B W S1 S2 T1 T2 I1 I2 W2 Y2 S1 S2 T1 T2 I1 I2 W2 Y2 S1 S2 T1 T2 I1 I2 W2 Y2 S1 S2 T1 T
Installation Indoor Air Quality equipment wiring diagrams Power and battery replacement Ventilation wiring This thermostat can be AC powered, battery powered, or both (to provide backup power for communication with the Control4 system). The thermostat uses four alkaline AA batteries. Batteries are optional but recommended if your thermostat was wired to run on AC power when installed.
Setup and testing Setup and testing Equipment Type selection switch This thermostat has the option of being used in heat pump or heat/cool systems. Use the Equipment Type selection switch on the back of the thermostat housing to select this option. This setting is displayed in the thermostat’s Installer System Settings menu under Equipment Type. Note: The thermostat reboots within 10 seconds after the switch position is changed. 18 Installer Setup menu Note: Select HC (Heat Cool) or HP (Heat Pump).
Setup and testing Change system settings Press button (Next) or button (Back) to page through settings. Press or setting. Setting description Setting option buttons to adjust the The following table contains the system settings and their details. Default settings are shown in bold. Some settings are only available based upon the value of other settings. HVAC Installer system settings table Press button (Done) to save and exit, or button (Cancel) to exit without saving.
Setup and testing HVAC Installer system settings table Factory default setting (bold) and setting range System setting Description 06. Heat/Cool: Fan Control in Heating Heat Pump: Auxiliary Equipment Type Heat/Cool: Determines if the thermostat or equipment controls the fan in heating. Heat Pump: Auxiliary equipment type. Gas/Oil Heat (Equipment Controls Fan) Electric Heat (Thermostat Controls Fan) 07. Extended Fan— Heat Extends the fan run time after a heat call ends.
Setup and testing HVAC Installer system settings table Factory default setting (bold) and setting range System setting Description 21. F irst Stage Differential Temperature difference from the setpoint required to turn on the first stage of heating or cooling. 1°F or 0.5°C 1°F to +9°F (0.5°C to 4.5°C) 22. S econd Stage Differential Temperature difference required to stage from the first stage of heating or cooling to the second. 1°F or 0.5°C 1°F to +9°F (0.5°C to 4.5°C) 23.
Setup and testing Indoor Air Quality system settings tables Humidifier system settings table The following tables contain the Indoor Air Quality system settings and their details. Default settings are shown in bold. Some settings are only present dependent upon the value of other settings. The use of the included outdoor temperature sensor (recommended) enables additional Indoor Air Quality functionality.
Setup and testing Humidifier system settings table Dehumidifier system settings table Note: A humidifier can be installed only if ventilation is not installed and Dehumidifier Control is not set to Whole Home. Note: Dehumidifier Control can only be set to Whole Home if ventilation and humidification are not installed.
Setup and testing 30 Ventilation system settings table Ventilation system settings table Note: Ventilation can be installed only if humidification is not installed and Dehumidifier Control is not set to Whole Home. Note: Ventilation can be installed only if humidification is not installed and Dehumidifier Control is not set to Whole Home.
Setup and testing Ventilation system settings table Note: Ventilation can be installed only if humidification is not installed and Dehumidifier Control is not set to Whole Home. Factory default setting (bold) and setting range System setting Description Home Size Selects the home size to be used for the ASHRAE calculation. If multiple ventilation systems are used, this should be set to the size of the zone that this thermostat is controlling. (Only available if Fresh Air Setup is set to ASHRAE.
Setup and testing Managing the ZigBee network connection The thermostat utilizes special button tap sequences for managing the ZigBee network connection. The button tap sequences are defined in the table. Button tap sequences that require a single (1) button should use the button on the top right of the thermostat. Button tap sequences requiring two (2) buttons should use the button and the button on the bottom right of the thermostat.
Setup and testing Each equipment test begins with the option of turning on the output or stage as shown below. Press or button to change the selection. Press button (Next) to accept the selection and proceed to the next step. If YES is selected, the thermostat tests the corresponding output. If NO is selected, the thermostat proceeds to the next step. Test to be run While the equipment test is active, the corresponding test information is shown.
Setup and testing System Test tables Heat pump heating equipment test (electric heat) Heat /cool heating equipment test Heat type Gas 1st Stage Test ON Gas 2nd Stage Test ON Electric 1st Stage Test ON Electric 38 W 2nd Stage Test ON W2 Y Y2 G ON ON ON ON O/B set to Compressor stages Aux stages 1 1 1st Stage Test 1 1 2nd Stage Test 2 1 1st Stage Test ON 2 1 2nd Stage Test ON ON 2 1 3rd Stage Test ON ON 1 2 1st Stage Test 1 2 2nd Stage Test ON 1 2 3rd St
Setup and testing Heat pump heating equipment test (gas heat) Heat/cool cooling equipment test O/B set to Compressor stages Aux stages 1 1 1st Stage Test 1 1 2nd Stage Test W W2 Y Y2 ON ON O W B G ON ON W2 Y 1st Stage Test ON 2nd Stage Test ON Y2 G ON ON ON ON Heat pump cooling equipment test 40 2 1 1st Stage Test ON 2 1 2nd Stage Test ON 2 1 3rd Stage Test 1 2 1st Stage Test 1 2 2nd Stage Test ON 1 2 3rd Stage Test ON ON ON ON ON ON ON ON ON O
Setup and testing Quick reference to controls and display Quick reference to controls and display Fan equipment test W W2 Y Y2 G ON Home screen Radio signal strength indicator Low battery indicator Message center Current indoor temperature Indoor Air Quality setting Temperature setting Humidification equipment test I1/ I2 G ON ON Equipment status Indoor Air Quality button (optional) Dehumidification equipment test I1/ I2 G ON ON Setpoint Adjust buttons System Mode setting Presets b
Troubleshooting Troubleshooting Cooling system does not respond ( Display is blank • • • • • • Check the circuit breaker and reset it if necessary. Make sure the heating and cooling system’s power switch is on. Make sure the furnace door is closed securely. If the thermostat is battery powered, make sure that fresh AA alkaline batteries are correctly installed.
Troubleshooting Error codes Heating equipment is running in cool mode Error codes • Check the Equipment Type selection switch to make sure it is set to match the installed heating/cooling equipment (see page 21). is not displayed • • Make sure that Installer System Setting number 02 (Control Setup) is set correctly. Change the System Mode to Heat, and set the temperature level above the current room temperature. If the thermostat enters an error mode, all outputs are turned off.
Thermostat features Specifications Thermostat features Specifications • • • • • • • • • • • 48 Up to 4 stage heat and 2 stage cool operation. Indoor air quality control. • Humidification (automatic or manual control). • Dehumidification. • Event-Based™ air cleaning. • Ventilation with temperature and humidity limits. Temperature control. Message center provides feedback and instructions. Dual power option (24VAC or battery). Air filter, humidifier, dehumidifier, and HVAC service reminders.
Specifications Thermal Outdoor and Remote temperature sensor Maximum distance: 300 feet (about 100 meters) Room temperature measurement Display range: 32° to 99°F (0° to 40°C) Outdoor temperature measurement Display range: -40° to 130°F (-40° to 55°C) Setpoint temperature range Heat: 40° to 90°F (4° to 32°C) Cool: 50° to 99°F (10° to 37°C) Setpoint humidity range Humidification: 10% to 50% R.H. Dehumidification: 40% to 90% R.H. U.S. Patent Number 8,146,376 (and other patents pending).
control4.com | 888.400.4070 61001048 B2206227B 2.
Regulatory Compliance & Safety Information for Contol4 Model C4-THERM-XX. USA & Canada Compliance FCC Part 15, Subpart B Unintentional Emissions Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation.
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
utilisateurs finaux doivent suivre les instructions de fonctionnement spécifiques pour satisfaire la conformité aux expositions RF. • • • L'appareil ne doit être utilisé ou installé à des endroits où il ya normalement au moins une séparation de 20 cm entre l'antenne et toute personne. Cet émetteur ne doit pas être co-localisés ou fonctionnement en conjonction avec une autre antenne ou un autre émetteur.
European Compliance Conformity of the equipment with the guidelines below is attested by the application of the CE mark. CE Declaration of Conformity Manufacturer’s Name: Manufacturer’s Address: CONTROL4 CORPORATION 11734 S.
Recycling Control4 understands that a commitment to the environment is essential for a health life and sustainable growth for future generations. We are committed to supporting the environmental standards, laws, and directives that have been put in place by various communities and countries that deal with concerns for the environment. This commitment is represented by combining technological innovation with sound environmental business decisions.