Instruction Manual

Getting to know your device
• One Zigbee-controlled outlet
• One always-on outlet
• Remote on/o control over the Control4 Zigbee network
• Manual on/o control with the Manual/Program button
• Programmable, single-color LED—Indicates light status and
status during network pairing process
• Over-the-air updates—Once joined to your Control4
Zigbee network, the Outdoor Plug-In Outlet Switch can
transparently receive updates through your Control4
controller
A B
C
D
E
F
A Line (hot)
B Neutral
C Ground
D Always-on outlet
E Manual/program button
F Controllable outlet
2.
1.
Tools you will need
IMPORTANT!
The device plugged into the Zigbee-controlled outlet
on this device must not exceed 1000W (incandescent),
1/2 HP motor, 1800W (15A) resistive, or 3.75A LED/CFL.
The total maximum rating for both outlets combined is
1800W (15A) resistive load.
3.
From breaker box
A
B
C
Wiring (Installation Instructions)
1. Shut o power to the circuit at circuit breaker or fuse box.
IMPORTANT! Verify power is OFF to switch box before continuing.
2. Remove wallplate.
3. Remove the outlet mounting screws.
4. Carefully remove the outlet from the wall box.
5. Disconnect the wires from the existing outlet. Label wires
according to the previous terminal connection.
6. There are three screw terminals on the Zigbee smart outlet; these
are marked (wire colors in the box may dier)
A LINE (hot) — Black (connected to power)
B NEUTRAL — White
C GROUND — Green/bare
Match these screw terminals to the wires connected to the existing
outlet.
7. Insert smart outlet into the box being careful not to pinch
or crush wires.
8. Secure the outlet to the box using the supplied screws.
9. Mount the wallplate.
10. Reapply power to the circuit at fuse box or circuit breaker
and test the system.
Basic operation
The device connected to the Zigbee-controlled outlet can be
turned on/o in two ways:
1. Manually from front program button.
2. Remotely from the Control4 system.
Observe important wiring information
Always follow the recommended wire strip length (5/8 in or
16mm) and wiring combination when making wiring connections.
Consult an electrician with questions or for professional
installation.
UL specifies the tightening torque for the screws is 14 Kgf-cm
(12 lbf-in).
IMPORTANT! The screw terminals in this receptacle are in-
tended to only be used with copper wire. Consult a qualified
electrician if you have aluminum wiring.
Wire gauge requirements
Use 14 AWG or larger wires suitable for at least 80° C for supplying
line (hot), neutral, and ground connections.
Controlled
Controlled
4.
Note: Requires OS 3.1.2 or newer.
1. In Composer, add the driver for the Receptacle Outlet
Switch (C4-V-ROSW120) to the project.
2. In the Network > Zigbee Network view, double-click the
driver for the Receptacle Outlet Switch to open the Identify
window.
3. Follow Composer’s on-screen instructions to identify the
Receptacle Outlet Switch; press the switch’s Program button
4 times.
4. After the Receptacle Outlet Switch is joined to the Zigbee
network, the LED status indicator stops blinking, and
the address for the Receptacle Outlet Switch appears in
Composer. The Receptacle Outlet Switch is now paired to the
Zigbee network and can be controlled.
Note: The LED blinks slowly until the switch is added to a
Control4 project.
Note: If the switch does not successfully join the network, the
auto-scan process will eventually time out (and the LED status
indicator will stop blinking rapidly). To restart the pairing process
following a timeout, press the top button 4 times quickly.
If prompted to enter the install code, refer to the QR code label
on the product. Enter the full code.
Example:
EUI: 000D6FFFFECD6DD6
Install code: 39F9-0CA3-09F2-4C6F-8080-131B-6EE4-1E95-D22E
Remove from Zigbee network (reset switch)
From Composer
In Composer under Network > Zigbee Network, select
the Receptacle Outlet Switch and click on Disconnect. The
Receptacle Outlet Switch will be removed from the Zigbee
network. All configuration parameters will be reset after the
Receptacle Outlet Switch is removed from the network.
Manual Reset
To manually reset and remove the Receptacle Outlet Switch
from the Zigbee network, press the Program/Manual button
13 times quickly (short presses).
5.
Controlled