User guide

Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running
the motor
Optimization NV Media Card
Advanced
parameters
Technical
data
Diagnostics
UL listing
information
98 Unidrive M100 User Guide
Issue Number: 1
10.8 Menu 8: Digital I/O
Figure 10-8 Menu 8 logic diagram
T10 Digital
I/O 1 State
08.031
T10 Output
Select
??.???
??.???
Any
unprotected
bit parameter
??.???
??.???
Any bit
parameter
x(-1)
x(-1)
08.011
T10 Digital
I/O 1 Invert
08.001
10.003
At Zero
Frequency
T10 Digital I/O 1
mm.ppp
mm.ppp
Key
Read-write
(RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown in their default settings
Frequency or
PWM output
0 or 1
2 or 3
T10 Digital I/O 1
source / destination A
08.021
T10 Digital I/O 1
source / destination B
08.121
T11 Digital input 2
08.002
T11 Digital
input 2 state
T11 Digital
input 2 invert
??.???
Any unprotected
User
enable
bit parameter
T11 Digital input
2 destination B
T11 Digital
input 2 control
T11 Digital input
2 destination A
??.???
x(-1)
06.038
08.122
08.082
08.022
08.012
1
1
T10 Digital
input 1 control
T10 Digital
output 1 control
08.09108.081