User guide

Safety
information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running
the motor
Optimization NV Media Card
Advanced
parameters
Technical
data
Diagnostics
UL listing
information
94 Unidrive M100 User Guide
Issue Number: 1
06.052
Motor Pre-heat
Current Magnitude
0to100% 0% RW Num US
06.059
Output Phase Loss Detection
Enable
Off (0) or On (1) Off (0) RW Bit US
06.060 Standby Mode Enable Off (0) or On (1) Off (0) RW Bit US
06.061 Standby Mode Mask 0 to 15 0 RW Bin US
06.071
Slow Rectifier Charge Rate
Enable
Off (0) or On (1) Off (0) RW Bit US
06.072 User Supply Select Off (0) or On (1) Off (0) RW Bit US
06.073 Braking IGBT Lower Threshold 0 to VM_DC_VOLTAGE_SET V
110 V drive: 390 V
200 V drive: 390 V
400 V drive: 780 V
575 V drive: 930 V
690 V drive: 1120 V
RW Num US
06.074 Braking IGBT Upper Threshold 0 to VM_DC_VOLTAGE_SET V
110 V drive: 390 V
200 V drive: 390 V
400 V drive: 780 V
575 V drive: 930 V
690 V drive: 1120 V
RW Num US
06.075
Low Voltage Braking IGBT
Threshold
0 to VM_DC_VOLTAGE_
SET V
0V RW Num US
06.076
Low Voltage Braking IGBT
Threshold Select
Off (0) or On (1) Off (0) RW Bit
06.077 Low DC Link Operation Off (0) or On (1) Off (0) RW Bit US
06.089 DC Injection Active Off (0) or On (1) Off (0) RO Bit NC PT US
RW Read / Write RO Read only Num Number parameter Bit Bit parameter Txt Text string Bin Binary parameter FI Filtered
ND No default value NC Not copied PT Protected parameter RA Rating dependent US User save PS Power-down save DE Destination
Date Date parameter Time Time parameter
Parameter
Range (Ú) Default(Ö)
Type
OL OL