Range
(Ú) Default (Ö)
Type
OL OL
01.001 Reference Selected ±VM_SPEED_FREQ_REF Hz
RO Num ND NC PT
01.002 Pre-skip Filter Reference ±VM_SPEED_FREQ_REF Hz
RO Num ND NC PT
01.003 Pre-ramp Reference ±VM_SPEED_FREQ_REF Hz
RO Num ND NC PT
01.004 Reference Offset ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num US
01.005 Jog Reference 0.00 to 300.00 Hz 1.50 Hz RW Num US
01.006 Maximum Reference Clamp ±VM_POSITIVE_REF_CLAMP Hz
50Hz: 50.00 Hz
60Hz: 60.00 Hz
RW Num US
01.007 Minimum Reference Clamp ±VM_NEGATIVE_REF_CLAMP1 Hz 0.00 Hz RW Num US
01.008
Negative Reference Clamp
Enable
Off (0) or On (1) Off (0) RW Bit US
01.009 Reference Offset Select 0 to 2 0 RW Num US
01.010 Bipolar Reference Enable Off (0) or On (1) Off (0) RW Bit US
01.011 Reference On Off (0) or On (1)
RO Bit ND NC PT
01.012 Reverse Select Off (0) or On (1)
RO Bit ND NC PT
01.013 Jog Select Off (0) or On (1)
RO Bit ND NC PT
01.014 Reference Selector
A1.A2 (0), A1.Pr (1), rES (2), PrESEt (3),
PAd (4), rES (5), PAd.rEF (6)
A1.A2 (0) RW Txt US
01.015 Preset Selector 0 to 9 0 RW Num US
01.016 Preset Selector Timer 0 to 400.0 s 10.0s RW Num US
01.017
Keypad Control Mode
Reference
±VM_SPEED_FREQ_USER_REFS Hz 0.00 Hz RO Num NC PT PS
01.021 Preset Reference 1 ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num US
01.022 Preset Reference 2 ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num US
01.023 Preset Reference 3 ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num US
01.024 Preset Reference 4 ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num US
01.025 Preset Reference 5 ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num US
01.026 Preset Reference 6 ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num US
01.027 Preset Reference 7 ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num US
01.028 Preset Reference 8 ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num US
01.029 Skip Reference 1 0.00 to 550.00 Hz 0.00 Hz RW Num US
01.030 Skip Reference Band 1 0.00 to 25.00 Hz 0.50 Hz RW Num US
01.031 Skip Reference 2 0.00 to 550.00 Hz 0.00 Hz RW Num US
01.032 Skip Reference Band 2 0.00 to 25.00 Hz 0.50 Hz RW Num US
01.033 Skip Reference 3 0.00 to 550.00 Hz 0.00 Hz RW Num US
01.034 Skip Reference Band 3 0.00 to 25.00 Hz 0.50 Hz RW Num US
01.035 Reference In Rejection Zone Off (0) or On (1)
RO Bit ND NC PT
01.036 Analog Reference 1 ±VM_SPEED_FREQ_USER_REFS Hz 0.00 Hz RO Num NC
01.038 Percentage Trim ±100.00 % 0.00 % RW Num NC
01.041 Reference Select Flag 1 Off (0) or On (1) Off (0) RW Bit NC
01.042 Reference Select Flag 2 Off (0) or On (1) Off (0) RW Bit NC
01.043 Reference Select Flag 3 Off (0) or On (1) Off (0) RW Bit NC
01.045 Preset Select Flag 1 Off (0) or On (1) Off (0) RW Bit NC
01.046 Preset Select Flag 2 Off (0) or On (1) Off (0) RW Bit NC
01.047 Preset Select Flag 3 Off (0) or On (1) Off (0) RW Bit NC
01.048 Preset Selector Timer Reset Off (0) or On (1) Off (0) RW Bit NC
01.049 Reference Selected Indicator 1 to 6
RO Num ND NC PT
01.050 Preset Selected Indicator 1 to 6
RO Num ND NC PT
01.051
Power-up Keypad Control Mode
Reference
rESEt (0), LASt (1), PrESEt (2) rESEt (0) RW Txt US
01.057 Force Reference Direction None (0), For (1), rEv (2) None (0) RW Txt
01.069 Reference in rpm ±VM_SPEED_FREQ_REF rpm
RO Num ND NC PT
01.070 Clamped Reference ±VM_SPEED_FREQ_REF Hz
RO Num ND NC PT
01.071 Alternative Reference ±VM_SPEED_FREQ_REF Hz 0.00 Hz RW Num NC PT
01.072 Alternative Reference Enable Off (0) or On (1)
RO Bit ND NC PT