6.1 Parameter descriptions
6.1.1 Pr mm.000
Pr mm.000 is available in all menus, commonly used functions are provided as text strings in
Pr mm.000 shown in Table 6-1. The functions in Table 6-1 can also be selected by entering the
appropriate numeric values (as shown in Table 6-2) in Pr mm.000. For example, enter 7001 in
Pr mm.000 to erase the file in NV media card location 001.
Table 6-1 Commonly used functions in Pr mm.000
Table 6-2 Functions in Pr mm.000
String Action
Save parameters
Save parameters when under voltage is not active and low voltage threshold is not
active
Load file 1 Load the drive parameters or user program file from NV media card file 001
Save to file 1 Transfer the drive parameters to parameter file 001
Load file 2 Load the drive parameters or user program file from NV media card file 002
Save to file 2 Transfer the drive parameters to parameter file 002
Load file 3 Load the drive parameters or user program file from NV media card file 003
Save to file 3 Transfer the drive parameters to parameter file 003
Show non-default Displays parameters that are different from defaults
Destinations Displays parameters that are set
Reset 50Hz Defs Load parameters with standard (50 Hz) defaults
Reset 60Hz Defs Load parameters with US (60 Hz) defaults
Reset modules Reset all option modules
Read Enc.NP P1 Transfer electronic nameplate motor parameters to the drive from the P1 encoder
Read Enc.NP P2 Transfer electronic nameplate motor parameters to the drive from the P2 encoder
Value Action
1000
Save parameters when Under Voltage Active (Pr 10.016) is not active and Low Under Voltage
Threshold Select mode (Pr 06.067 = Off) is not active.
1001 Save parameter under all conditions
1070 Reset all option modules
1233 Load standard (50 Hz) defaults
1234 Load standard (50 Hz) defaults to all menus except option module menus (i.e 15 to 20 and 24 to 28)
1244 Load US (60 Hz) defaults
1245 Load US (60 Hz) defaults to all menus except option module menus (i.e 15 to 20 and 24 to 28)
1253 Change drive mode and load standard (50 Hz) defaults
1254 Change drive mode and load US (60 Hz) defaults
1255 Change drive mode and load standard (50 Hz) defaults except for menus 15 to 20 and 24 to 28
1256 Change drive mode and load US (60 Hz) defaults except for menus 15 to 20 and 24 to 28
1299 Reset {Stored HF} trip.
2001*
Create a boot file on a non-volatile media card based on the present drive parameters including all
Menu 20 parameters
4yyy* NV media card: Transfer the drive parameters to parameter file xxx
5yyy* NV media card: Transfer the onboard user program to onboard user program file xxx
6yyy*
NV media card: Load the drive parameters from parameter file xxx or the onboard user program from
onboard user program file xxx
7yyy* NV media card: Erase file xxx