User guide

68 Unidrive SP Short Form Guide
www.controltechniques.com Issue Number: 2
Table 8-1 SMARTCARD data blocks
Data transfer to or from the SMARTCARD is indicated by one the following:
SM-Keypad: The decimal point after the fourth digit in the upper display will flash.
SM-Keypad Plus: The symbol 'CC' will appear in the lower left hand corner of the
display.
The card should not be removed during data transfer, as the drive will produce a trip. If
this occurs then either the transfer should be reattempted or in the case of a card to
drive transfer, default parameters should be loaded.
Transferring data
Data transfer, erasing and protecting the information is performed by entering a code in
Pr xx.00 and then resetting the drive as shown.
SMARTCARD codes
Where yyy indicates the block number 001 to 999. See Table 8-1 for restrictions on
block numbers.
Data block Type Example use
1 to 499 Read/Write Application set-ups
500 to 999 Read only Macros
Code Action
2001
Transfer drive parameters as difference from defaults to a bootable SMARTCARD block in data block
number 001
3yyy Transfer drive parameters to a SMARTCARD block number yyy
4yyy Transfer drive data as difference from defaults to SMARTCARD block number yyy
5yyy Transfer drive Onboard PLC program to SMARTCARD block number yyy
6yyy Transfer SMARTCARD data block yyy to the drive
7yyy Erase SMARTCARD data block yyy
8yyy Compare drive parameters with block yyy
9555 Clear SMARTCARD warning suppression flag (V01.07.00 and later)
9666 Set SMARTCARD warning suppression flag (V01.07.00 and later)
9777 Clear SMARTCARD read-only flag
9888 Set SMARTCARD read-only flag
9999 Erase SMARTCARD
If the read only flag is set then only codes 6yyy or 9777 are effective.
NOTE