Hardware manual

5901 High Speed Dialup Modem Hardware Manual
October 19, 2007
66
NOTE: Compression is omitted if protocol is NONE.
Line Speed = Asymmetric rates are displayed as /rate:TX/rate:RX, e.g., /1200
TX/75 RX.
Symmetric rates are displayed as a single DCE rate, e.g., 14400.
Voice and Data = Blank for Data mode only.
“SVD” for AudioSpan analog simultaneous audio/voice and data.
“DSVD” for digital simultaneous voice and data
“V70” for G.729A digital simultaneous voice and data.
10.7 AT% Command Set
10.7.1 %7 - Plug and Play Serial Number
Sets and stores eight serial numbers in hex format used for serial Plug and Play and for ISA Plug
and Play which use the Rockwell 11596 Plug and Play device. Applicable to Desktop configuration
only.
Command: %7<8 hex numbers><same 8 hex numbers>
Example: %7<8 hex numbers><same 8 hex numbers>
Result Codes:
OK <8 hex numbers><same 8 hex numbers>
ERROR Otherwise
To display the stored serial number, issue AT"?<cr>.
10.7.2 %8 - Plug and Play Vendor ID and Product Number
Sets and stores Vendor ID and product number for serial Plug and Play and for ISA Plug and Play
which use the Rockwell 11596 Plug and Play device. Applicable to Desktop configuration only.
Command: &8<3 ASCII characters><4 hex numbers><same 3 ASCII characters><same 4 hex
numbers><cr>
Example: %8<3 ASCII characters><4 hex numbers><same 3 ASCII characters><same 4 hex
numbers><cr>
Result Codes:
OK <3 ASCII characters><4 hex numbers><same 3 ASCII characters><same 4 hex
numbers>
ERROR Otherwise
10.7.3 %Cn - Enable/Disable Data Compression
Enables or disables data compression negotiation. The modem can only perform data compression
on an error corrected link.
The parameter value, if valid, is written to S41 bits 0 and 1.
Command: %Cn
n Decimal number corresponding to the selected option.