User Manual

TRAIN CHIEF® II LRCS W/ Lightweight OCU-BT – OPERATORS MANUAL
95-00-0-062, Rev 09 4-5 Control Chief Corporation
4.2.4 OCU Setup
All switches and levers should be in their OFF positions.
Set INDEPENDENT BRAKE Selector to fifth position for FULL service brake application
Check AUTO BRAKE toggle in center position
Place HORN/BELL switch in OFF position (toward operator)
Place Reverser switch in NEUTRAL position.
Throttle selector in HALT position.
E-Stop pulled out.
OCU not tilted.
Note:
The operator should be wearing the break-away vest by this time. The unit should
be secured to the break-away vest. The operator can adjust the equipment straps
so the unit fits on the chest at a comfortable position. The break-away vest also has
a waist belt to accommodate a comfortable fit using one of three belt sizes.
Turn on the Lightweight OCU by pressing the Power-On pushbutton at the lower right hand
corner of the unit (see section 3.2.3). At power-on the OCU will perform a Power-On-Self-Test
(POST). When POST has completed successfully the unit is ready for to be assigned to a
Train Chief® II equipped locomotive.
A successful POST is indicated by the flashing OCU indicators and appropriate
display message (“READY TO REGISTER WITH LOCOMOTIVE>>OCU>LOCO”
The last eight characters of the scrolled message remain on the display).
If an error is detected during the POST an appropriate error message will be
displayed and the unit will be disabled. See the troubleshooting section for further
details.