User guide
Composer Pro User Guide
Copyright © 2012 Control4. All Rights Reserved.
Saved: 1/20/2012 1:31:00 PM
200-00005 Composer Pro
User Guide Part 1
Page 99 of 199
Always On to keep the backlight on constantly. When using batteries for power with power
stealing enabled, the Always On option is not recommended.
Battery—Shows the power source or battery level; e.g., "Externally Powered."
Time Format (Date and Time)—Lets you set preferences regarding Date Format
(MM/DD/YYYY or DD/MM/YYY) and Time Format (12 h or 24 h). Click the Sync Time
button under Time Format to update the time on your Thermostat manually to the
Controller. (The Thermostat also updates automatically at 3:00 AM each morning.)
Network—Displays informational boxes that provide ZigBee networking information (MAC
and Firmware Version).
Select Apply to... to apply the current properties to the selected Wireless Thermostats.
Advanced Device Configuration
Control4 has enhanced the available Thermostat settings to allow users and installers to modify
engage and cutoff temperature deltas as well as maximum and minimum run time, off, and delay
times so that the Thermostat can be configured to run optimally with any HVAC system.
Note: Allowing such fine tuning of all settings can result in setting improper values and
combination of values to cause the HVAC system to run less than optimal. To prevent thrashing
the cool and heating engage (constant heat, then cool, engagement), cutoff and set points are
enforced to have at least a one (1) degree difference for engage temperatures.
The formula for the dependency of these values is:
Heat/cool engage delta—Opposite stage (if heat engage, then cool cutoff and visa versa) cutoff
delta + set points delta (cool set point – heat set point) >=1
The screen below shows the Advanced Device Configuration properties.