User guide
Composer Pro User Guide
Copyright © 2012 Control4. All Rights Reserved.
Saved: 1/20/2012 1:31:00 PM
200-00005 Composer Pro
User Guide Part 1
Page 93 of 199
Modifiable properties include:
Invert Sensor: Depending on the sensor type, the Controller sends a small amount of voltage
through the sensor to close it, if for example when a door is closed with feedback indicating such.
You use Invert Sensor if you want to feedback to be the opposite.
Enable Debounce Timer: Sets an amount of time that lapses before the sensor triggers to on.
Debounce Time(ms): The amount of time in milliseconds before the sensor state changes to on.
4. Check the Enable Debounce Timer box.
5. In the Debounce Time(ms) (in milliseconds) drop-down menu, select to delay notification of the
contact state (the default is 100 milliseconds).
2.5.10 Configuring HVAC Systems
Use the Control4
®
Composer Pro System Design and Connections views to configure a Control4
Wireless Thermostat. Control4 also supports multiple third-party thermostat models.
Note: Previous releases of Composer Pro documentation included instructions about how to configure
third-party products and older versions of the Wireless Thermostat. Starting with OS 2.0, third-party
device configurations are no longer included in the documentation, although they are still supported in
the drivers list (for example, EnviraZone and Aprilaire RS232). Refer to previous releases of the
Composer Pro User Guide for information about these third-party drivers and examples of older
Thermostat models.
These sections provide information about the Wireless Thermostat.