The minimum separation between the Heating/Cooling Engage and Cutoff points has
been reduced from two (2) degrees to one (1) degree Fahrenheit.
Improvements to the Control4 Thermostat’s ability to control residential heat pump
systems.
New Advanced Properties: Disabling The Call For Auxiliary HeatSetting the Auxiliary
Heat Stage Delay to 255 will prevent the Thermostat from making a call for auxiliary heat.
Values in the range of 0 to 254 will be the number of minutes the Thermostat engages the
heat pump before calling for auxiliary heat.
New Advanced Properties: Heat Pump and Auxiliary Heat OverlapThe Auxiliary Heat
Cutoff Delay is the length of time in seconds that the Thermostat allows concurrent
operation of the heat pump and auxiliary heat. A value of 255 will cause them to run
together indefinitely (subject to maximum run times and/or achieving the goal
temperature).
Card Access. Updated Card Access firmware for the Wireless Contact Relay and Heavy
Duty Power Switch devices that enables them to support parenting functionality. This change
will benefit installations with sparse meshes that are using these Card Access devices to
extend the mesh.
Black & Decker Smart Code Door Locks.
Improvements were made to the Black & Decker Door Lock driver and firmware
(01.05.00).
The Black & Decker door lock doesn’t update until after 3 AM; a message “update failed”
will appear until the update takes place. The following functionality does not work until the
locks have been completely updated:
o Email notifications
o Incorrect status feedback UI and Composer Pro
o Is controllable from Composer Pro and bound to a keypad
o Message “Unknown response from lock” appears in the last status message
dialog box in Composer Pro
o Firmware Version will state “Not Connected”
Media. Changed the media lookup service to c4lookup.
Security. Added a check to the SSL server certificate creation to detect a malformed
certificate. If detected, the server certificate will be recreated automatically when the
Controller is rebooted. This corrects the occasional occurrence of "project locked" when not
being updated.
2.11.1.2 Release 1.8.0
Agents
The Composer Pro Timer agent interface has been updated to allow for specification of
timer duration in a more flexible way. Timer selection is now in the format hh:mm:ss.
Now include Control4 system and user-defined variables in the templates created using
the E-mail Notification agent. To use this new capability, the Installer can create or
modify email templates using Composer Pro, Agents, E-mail Notification, and then use
the ‘Add Variable’ option.
Deleting the Timer agent doesn’t remove the programming.