Product Info
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 -
Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
6
PROCESS DATA OUTPUT
PROCESS DATA REPRESENTATION
PROCESS DATA INPUT
PROCESS DATA STRUCTURE - SCAN UID MODE
Bitoffset
Byte 7 6 5 4 3 2 1 0
0 RFU ERR TAG ANT RFU
1 ERROR CODE ALR1 ALR2
2 RSSI
3-10 UID 0 - UID 7
11-18 STTI 0 - STTI 7
19-26 TIRT 0 - TIRT 7
27-31 RFU
Bitoffset
Byte 7 6 5 4 3 2 1 0
0 RFU N_ANT RFU
1-31 RFU
Name Value Description
ERR
0 Command executed and no error
1 Command executed but error
TAG
0 No tag present in front of the RWM
1 Tag present in front of the RWM
ANT
0 RF field OFF
1 RF field ON
ERROR CODE See ERROR CODE list below
ALR1
0 Alarm 1 OFF
1 Alarm 1 ON
ALR2
0 Alarm 2 OFF
1 Alarm 2 ON
RSSI RSSI signal level coming from the transponder
UID 0 Transponder UID LSB
UID 7 Transponder UID MSB
STTI 0 System time - Transponder IN LSB
STTI 7 System time - Transponder IN MSB
TIRT 0 Transponder IN RANGE time LSB
TIRT 7 Transponder IN RANGE time MSB
Name Value Description
N_ANT
0 Switch ON RF field
1 Switch OFF RF field
ERROR CODE Description
1 CommandNotSupported
2 FormatError
3 OptionNotSupported
5 CommandProblem
6 CommTagError
15 TagError
16 NoMemoryBlock
18 BlockProtected
21 CRCError
22 CollisionError
23 TimeOutError
24 AppMemError
25 AppQueError
26 AppLOGRnError
27 AppLOGPSWError
255 AppGeneralError