Product Info
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 -
Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
5
DEVICE DESCRIPTION
48
h
01
h
Function Tag R/W char [] <user string, 32 byte (variable length)>
<vendor spe-
cific>
02
h
Location Tag R/W char [] <user string, 32 byte (variable length)>
<vendor spe-
cific>
DEVICE CHARACTERISTIC
49
h
01
h
RFID Compatibility R char [] “13.56 MHz, ISO15693” -
02
h
Read-write distance max R char [] “60 mm with diam 50mm SLIX tag” -
03
h
Supply voltage range (Ub) R char [] “11...32 VDC” -
04
h
Max. output current R char [] “≤ 200 mA” -
05
h
Ambient temperature
range TA
R char [] “-25...+80°C” -
06
h
Storage temperature
range TS
R char [] “-25...+80°C “ -
07
h
Enclosure rating R char [] “IP68 & IP69K“ -
TAG TIMING
4A
h
01
h
System Time - Transponder IN R uint64
Record system time when transponder enters the
RWM detection range [ms]
-
02
h
System Time - Transponder OUT R uint64
Record system time when transponder leaves the
RWM detection range [ms]
-
03
h
Transponder IN RANGE Time R uint64 IN RANGE = Transponder OUT - Transponder IN -
SECURITY
58
h
01
h
Security Mode R/W unit8
0 = Security mode inactive
1 = SLI-S or SLIX-2 Securtiy mode active (perform
a login with the specified password before each
read or write operation)
12 = EM4233SLIC Securtiy mode active (perform
a login with the specified password before each
read or write operation)
00
h
02
h
Password W uint32
Password is never readable to avoid end-user ap-
plication counterfeiting
8 x 00
h
DIAGNOSTIC
59
h
01
h
System Time R uint64
The system time is reset at each RWM power
down or in case the standard command 128 =
Device Reset is sent to the RWM. System Time
is given in [ms]
-
02
h
Successful Login counter R uint32
Counter which counts the number of successful
transponder Login since last RWM startup / reset
-
03
h
Error Login counter R uint32
Counter which counts the number of unsuccessful
transponder Login since last RWM startup / reset
-
04
h
Error counter R uint32
Counter which counts the number of RMW error
since last RWM startup / reset
-
05
h
Power-on cycles R uint32
Counter which counts the number of RMW Power
on. This counter cannot be reset
-