Product Info
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 -
Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
4
TAG INFO
43
h
01
h
UID R uint64
Data available only if transponder is in the RWM
detection range when TAG INFO fields are read
-
02
h
Transponder DSFID R uint8
Data available only if transponder is in the RWM
detection range when TAG INFO fields are read
-
03
h
Transponder AFI R uint8
Data available only if transponder is in the RWM
detection range when TAG INFO fields are read
-
04
h
Number of Memory Blocks R uint8
Data available only if transponder is in the RWM
detection range when TAG INFO fields are read
-
05
h
Memory Block Size R uint8
Data available only if transponder is in the RWM
detection range when TAG INFO fields are read
-
06
h
IC Reference R uint8
Data available only if transponder is in the RWM
detection range when TAG INFO fields are read
-
07
h
RSSI R uint8
Data available only if transponder is in the RWM
detection range when TAG INFO fields are read
-
UID LIST
44
h
01
h
Tag history 1 R uint64 Last transponder UID seen by RWM -
02
h
Time stamp Tag history 1 R uint64
System time record when tag 1 entered in the
RWM range
-
03
h
Tag history 2 R uint64 - -
04
h
Time stamp Tag history 2 R uint64
System time record when tag 2 entered in the
RWM range
-
05
h
Tag history 3 R uint64 - -
06
h
Time stamp Tag history 3 R uint64
System time record when tag 3 entered in the
RWM range
-
07
h
Tag history 4 R uint64 - -
08
h
Time stamp Tag history 4 R uint64
System time record when tag 4 entered in the
RWM range
-
09
h
Tag history 5 R uint64
First transponder UID seen by RWM (on a shift
register of 5 UIDs)
-
0A
h
Time stamp Tag history 5 R uint64
System time record when tag 5 enters in the RWM
range
-
SIO COUNTER
45
h
01
h
SIO Counter C/Q1 R/W uint32
Counter value which reacts on switching events
of C/Q1
00
h
, 00
h
,
00
h
, 00
h
46
h
01
h
SIO Counter Q2 R/W uint32
Counter value which reacts on switching events
of Q2
00
h
, 00
00
h
, 00
h
ALARM
47
h
01
h
Measurement Alarm 1 Con-
figuration
R/W uint8
0 = Always OFF
1 = Active
00
h
02
h
Measurement Alarm 1
Threshold
R/W uint32
ALR1 goes TRUE if :
SIO Counter Q1 ≥ Alarm 1 Threshold
SIO Counter Q2 ≥ Alarm 1 Threshold
RSSI ≤ Alarm 1 Threshold
Tag IN RANGE Time ≤ Alarm 1 Threshold
00
h
, 00
h
,
00
h
, 00
h
03
h
Measurement Alarm 1
Source
R/W uint8
0 = SIO counter Q1
1 = SIO counter Q2
2 = RSSI
3 = Tag IN RANGE Time [ms]
00
h
04
h
Measurement Alarm 2 Con-
figuration
R/W uint8
0 = Always OFF
1 = Active
00
h
05
h
Measurement Alarm 2
Threshold
R/W uint32
ALR2 goes TRUE if :
SIO Counter Q1 ≥ Alarm 2 Threshold
SIO Counter Q2 ≥ Alarm 2 Threshold
RSSI ≤ Alarm 2 Threshold
Tag IN RANGE Time ≤ Alarm 2 Threshold
00
h
, 00
h
,
00
h
, 00
h
06
h
Measurement Alarm 2
Source
R/W uint8
0 = SIO counter Q1
1 = SIO counter Q2
2 = RSSI
3 = Tag IN RANGE Time [ms]
00
h