Product Info
CONTRINEX AG Industrial Electronics
route du Pâqui 5 - P.O. Box - CH 1720 Corminboeuf - Switzerland - Tel: +41 26 460 46 46 -
Fax: +41 26 460 46 40 - Internet: www.contrinex.com - E-mail: info@contrinex.com
2
MOUNTING RECOMMENDATIONS
WIRING DIAGRAM PIN ASSIGNMENT
CLEARANCE
Read/write modules must not mutually influence each other. For this reason, a minimum distance of b between the devices must be observed.
A : metal free zone
B : sensing face
C : support
a : 80 mm
b : x mm
c : 90 mm
d : 40 mm
U
b
11...32 VDC
I
A
< 200 mA
A1 : RS-485 - B
A2 : RS-485 - A
3
1
4
2
M12
COMMUNICATION SETTINGS
RS-485 characteristics Value for RLH-C44PA-NSS
Data transfer rate (default in bold) 115 200 / 38 400 / 19 200 baud
Number of bits 8
Number of stop bits 1
Parity No
199
198
197
196
C7
C6
C5
C4
006
005
004
003
002
001
000
06
05
04
03
02
01
00
Block-Adressen
Adresses des blocs
Addresses of the blocks
Byte 0Byte 1
16 bit
HEXDEC
MEMORY STRUCTURE OF THE READ/WRITE MODULE
The Read/Write Module has a user memory of 3200 bits organized in 200 blocks of 16 bits. Each block is addressable separately by means of the
commands Write RWM and Read RWM.