Instruction Manual
3 - 21
Table 3-12 Follower Mode Control Parameters Example B
CP Parameter Name Parameter Value
CP-33 Max RPM Lead 1800
CP-34 Max RPM Feedback 1800
CP-30 PPR Lead 60
CP-31 PPR Feedback 30
CP-21 Follower E.U. 50
CP-03 Follower Setpoint 1 50
CP-04 Follower Setpoint 2 70
The ML–Trim will adjust and monitor the speed of the motors to achieve the desired
gallons/minute. That completes the scaling and setpoint information for Example B.
After the Control Parameters for the Scaling and for the Follower setpoint have been
entered, you can enter the Control Parameters for the Acceleration/Deceleration of the
Follower mode. The Control Parameters for Acceleration/Deceleration are identical for
both the Master and the Follower modes of operations. Acceleration/Deceleration is
discussed in
Operation: Control Parameters, Acceleration/Deceleration,
page 3-26.