4.3.3 ADDING VENT SECTIONS
A
dd chimney sections, according to the manufacturers installation instructions. The chimney must extend at
least, 3 feet above its point of contact with the roof and at least 2 feet higher than any wall, roof, building or
obstacle within 10 feet horizontally.
59.1A
3 FT
MIN
3 FT
MIN
3 FT
MIN
3 FT
MIN
10 FT OR
MORE
LESS THAN
10 FT
FLAT ROOF
WALL
2 FT
MIN
10 FT TO
NEAREST
ROOFLINE
RIDGE
LESS THAN
10 FEET
2 FT MIN
2 FT
MIN
4.3.4 INSTALLING NATURAL VENT
ADAPTER INSTALLATION:
• Remove the spill switch bracket from the rear of the adapter.
• Gently pull the two wire terminals (located inside the 7" fl ue
collar at the top of the appliance) out approximately 8".
• Bring the wires through the lower hole in the adapter and out
the spill switch opening. To pass the wires through the hole
more easily, temporarily take the two terminals together.
• With the spill switch opening aligned to the back of the
appliance, take hold of the adaptor base and push the crimped
edge into the appliance fl ue collar.
• Connect the wire terminals to the spill switch and re secure the
bracket.
For aesthetics, the adaptor has been designed to accept a standard
matte black 7" appliance pipe and a decorative black band (standard
with the GS150KT). Both are available from your local authorized
dealer / distributor.
SW ITCH
SPILL
ADAPTER