REPLACING UVC LAMP
When the UV Lamp light on the Control Panel (Fig. 1) turns orange, the UVC lamp
should be replaced within 30 days.
1. Turn the unit off and unplug the power cord from the electrical outlet.
2. Using index fingers, squeeze the locking tabs inward toward the center of the
grille. Lift the grille and remove (Fig. 2).
3. Rotate UVC lamp one-quarter turn, top-to-rear, and remove lamp (Fig. 3).
4. Insert new UVC lamp by rotating one-quarter turn (top-to-front).
5. Replace grille by pressing it into position until it locks. The aluminum reflector must
be positioned over the lamp nearest the front of the unit (Fig. 3a).
6. Reset UVC lamp timer by lightly pressing the UV Lamp Reset button on the
Control Panel with a pin or similar object. The UV Lamp light will turn green,
indicating the timer has been reset.
Fig. 2
Fig. 3aFig. 3