Maintenance Instructions CX1000 Portable Air Purifier
PRODUCT SPECIFICATIONS Manufacturer: Continental Fan Manufacturing Inc. Model: CX1000 Portable Air Purifier Unit Dimensions: 21.3" W x 19.0" H x 8.0" D Unit Weight: 23 lbs Max Airflow: 265 cfm Power Consumption: 110 watts Voltage: 1/120V/60 Maximum Amps: 0.95 UV Range: 254 NM (germicidal) Filters: 5 micron pre-filter 0.
BEFORE INSTALLATION IMPORTANT NOTICE! READ AND SAVE THESE INSTRUCTIONS WARNING 1. 2. 3. To reduce the risk of electric shock and injury, do not place in a window. CX1000 Portable Air Purifier is designed to be used on a flat and level surface, and may not work properly on an uneven surface. Always place the CX1000 at least 12 inches (30 centimeters) away from heat sources such as stoves, radiators, or heaters. Do not immerse the CX1000 in water, as permanent damage may occur.
OPERATION 1. Press the Power button on the Control Panel to turn on the CX1000. Lights on the panel will illuminate and the UVC lamp will turn on (Fig. 1). 2. Look into the air outlet at the top of the CX1000 to confirm that the UVC lamp is operating with a faint blue glow. 3. Set the fan speed to the correct room size. Room area (length x width) is listed in both square feet and square meters at either side of the green bar light panel underneath Room Size / Fan Speed. Determine the area of the room.
MAINTENANCE Control Panel lights indicate when maintenance is required, and if either the UVC lamp or the air filters need to be cleaned or replaced. AIR FILTERS The filters have a useful life of one year in a typical residential environment. • Green light - Filters are clean. • Orange light - Filters have been in service for more than 5 months. • Red light - Filters have been in service for more than 6 months and require cleaning.
REPLACING UVC LAMP When the UV Lamp light on the Control Panel (Fig. 1) turns orange, the UVC lamp should be replaced within 30 days. 1. Turn the unit off and unplug the power cord from the electrical outlet. 2. Using index fingers, squeeze the locking tabs inward toward the center of the grille. Lift the grille and remove (Fig. 2). Fig. 2 3. Rotate UVC lamp one-quarter turn, top-to-rear, and remove lamp (Fig. 3). 4. Insert new UVC lamp by rotating one-quarter turn (top-to-front). 5.
REPLACING FILTERS When the Air Filter and UV Lamp service lights on the Control Panel (Fig.1) turn red, the filters and UV lamp should be replaced. 1. Turn the unit off and unplug the power cord Fig. 4 from the electrical outlet. 2. Rest the air purifier on its back to access the bottom of the unit (Fig. 4). 3. Press in the locking clips at each end of the front grille. 4. Lift the bottom of grille and slide it out from the top of the unit (Fig. 5). 5.
LIMITED WARRANTY Subject to the provisions of the clauses herein, Vendor agrees to correct any defect or defects in workmanship or materials which may develop under proper and normal use, by repair or by replacement of the defective part or equipment, at Vendor’s option, FOB factory. Unless otherwise stated, the warranty period shall be one (1) year from date of shipment. The exceptions to this warranty period are: CX Air Purifiers - Two (2) years www.continentalfan.com www.continentalf an.