6. Power Wiring and Cable Management 
The Basic Power Cable is used on Non-J1708/J1939 and non-OBDII installs. It is also used 
on J1708/J1939 installs with switched power issues (as indicated by flashing “Status” 
LED with engine running). See General Guidelines and the following requirements. 
1)  All power leads must be connected to the vehicles protected circuitry (for example, 
the fuse panel and circuit breaker panel protected circuits). Never electrically 
connect Zonar equipment to unprotected circuits (for example, directly to the 
battery).  
2)  All power leads (red and white) must be protected with a 3 - 5 Amp fuse and inline 
fuse holder (included) for optimal system protection. 
3)  Electrical fuses should be installed as close as possible to the source of power. 
4)  For vehicles equipped with “noise kill” switches (late model school buses) – Do not 
wire any Zonar equipment to the “noise kill” circuitry. 
6.1. Power Cable Wires 
 Red – Constant DC (+8 VDC to +32 VDC), dependent on system type 
 Black – Battery Ground 
 Green - Chassis ground 
 White - Switched Power o Engine running (+8 VDC to +32 VDC) o Engine not running (0 
VDC) o Engine not running (key position ACC or Accessory Mode) (0 VDC) 
The white wire must be connected to a power source that is active only when the 
engine is running or the system will not track idle time properly. 
Note: Please contact the vehicle manufacturer for any specific electrical questions. 