User's Manual

5. Setup and Status Display
NZ2WL - xxx
35
Statistic Node Address
This item is available when the wireless link mode is "Compatible Infrastructure", the unit type is
"Station", and the multi-client function is "Disable". Enter the MAC addresses of the PCs connected to
the product. Generally, set this item when connected to a receive-only device, such as a POS terminal.
Enter the MAC address "00
-
00
-
00
-
00
-
00
-
00", which consists of nothing but 0, meaning the function is
disabled, when not using the function.
When specifying a MAC address, enter a hyphen (-) at intervals of two characters.
(Example: 01-23-45-67-89-ab)
Factory default setting
:
00
-
00
-
00
-
00
-
00
-
00
Maximum Number of Stations to Log In
This item available when the unit type is "Access point". The number of stations to log in AP is limited.
Enter a value between 1 and 254.
Normally, the maximum number is 254 units, but it varies depending on the encryption function of the
wireless LAN in use.
The maximum number is 124 units when using IEEE 802.1X encryption.
The maximum number is 128 units when using AES-based WPA/WPA2/WPA-AUTO or WPA-
PSK/WPA2-PSK/WPA-AUTO-PSK encryption.
The maximum number is 32 units when using TKIP-based WPA/WPA2/WPA-AUTO or WPA-
PSK/WPA2-PSK/WPA-AUTO-PSK encryption.
Factory default setting
:
254
Table 5.4. Maximum Login
Encryption Units
Encryptions other than those described below 254
IEEE802.1X 124
AES (when using WPA function) 128
TKIP (when using WPA function) 32
Roaming Threshold
This item is available when the unit type is “Station”. When the RSSI value of the currently connected
access point is smaller than the setting value, the product searches for a roaming-accessible access point
and roams into that access point if possible. Threshold can be set from 0 to 95. Increasing this value
makes roaming easier and decreasing it makes roaming harder.
Factory default setting
:
IEEE802.11a/g
24
IEEE802.11b
24