FX-DS540-APDL-U
75
Software Specifications
Table 8.3. Software Specifications
Specification FX-DS540-APDL-U
Protocols IP(RFC791), ICMP(RFC792), UDP(RFC768),
TCP(RFC793,896), ARP(RFC826),
HTTPD(RFC1866), TELNET(RFC),
FTPD(RFC959), TFTP(RFC783,906),
DHCP(RFC2131)
Environmental Specifications for Installing the FX-DS540-APDL-U
Table 8.4. Environmental Specifications (Environmental Specs)
Specification FX-DS540-APDL-U
DC supply voltage(Input) 3.3VDC±5% 1.3A(Max.) (AC adapter(bundled))
Operating temperature 0 to 50°C
Operating humidity 10 to 90%RH (No condensation)
Airborne dust Not extreme
Corrosive gases None
Permitted transient power failure 17ms or less (100VAC@25°C)
An automatic reset is performed when low voltage is detected.
Table 8.5. AC Adapter Environmental Conditions (Environmental Specs)
Specification FX-DS540-APDL-U’s accessory
AC supply voltage(Input) 100 to 240VAC 0.3A(Max.)
AC supply frequency 47 to 63Hz
DC supply voltage(Output) 3.3VDC±5% 1.5 A(Max.)
Operating temperature 0 to 50°C
Operating humidity 20 to 90%RH (No condensation)
Airborne dust Not extreme
Corrosive gases None