Foreword Please read the User Manual carefully before using this product. The User Manual which describes the operating procedures should be followed strictly. This manual detailed introduce the steps must be noted when using the product, operation which may result in abnormal, the risk may cause personal injury and product damage and other contents, refer to the chapters for details.
Contents Chapter1 Functions and Purpose ............................................................................................. 1 Chapter2 Safety Precautions ................................................................................................... 2 2.1 Operation about AC Adapter ..................................................................................... 3 2.2 Operation about Batteries ..........................................................................................
Chapter1 Functions and Purpose Description of functions: The Sphygmomanometer apply to measure the non-invasive blood pressure of human (adult, pediatrics, neonate), each user can store 100 items records of measurement results at most. Each record includes detailed measuring time, systolic pressure, diastolic pressure, average pressure, pulse rate and record number, etc. With 2.8 inch color LCD screen, clear interface, the function of data review is complete.
Chapter2 Safety Precautions ●Before use, carefully read the "Safety Precautions" for a correct use. ●To prevent users suffered hurt or damnification due to improper use,see "Safety Precautions",and use this product properly. For safety reasons, be sure to comply with safety precautions. Note If not to use correctly, it exists that a potentially hazardous situation which may result in injury to the user or patient or damage to the equipment or other property.
Note Self-diagnosis and treatment using measured results may be dangerous.Follow the instructions of your physician. Please hand measurement results to the doctor who know your health to accept diagnosis. For severe blood circulation disorder or arrhythmia patients, please use the device under the guidance of a doctor. Otherwise it may lead to acute hemorrhage, or measurement error as a result of squeezed arm.
2.2 Operation about Batteries Note Please use 4 "AA" manganese or alkaline batteries, do not use batteries of other types. Otherwise it may cause fire. New and old batteries, different kinds batteries can not be confusion. Otherwise it may cause battery leakage, heat, rupture, and damage to Electronic Sphygmomanometer. Please don't put wrong the positive and negative of battery. When the batteries power exhausts, replace with four new batteries at the same time.
Chapter3 Main Unit Display Cuff Plug Cuff Air Plug Up/Down button Memory button AC adapter socket Menu button USB socket On /Off button Start /stop button Accessories: Adult Cuff Dry Battery (Cuff specification: limb circumference 22-32cm (middle part of upper arm)) User Manual Optional Accessories: AC adapter Input: voltage: AC 100V~220V frequency: 50Hz/60Hz Rated current:AC 150mA Output: DC 6.0V±0.2V 1.0A or DC5.0V±0.2V 1.
SpO2 Probe: Y10UCH150 A. SpO2 measurement Range:0%~100% Error: 70~100%:±2%;Below 70%:unspecified B. Pulse rate measurement Range:30bpm~250bpm Error: ±2bpm or ±2%(select the larger) C. Optical sensor: red light(wavelength: 660nm, 6.65mW) infrared light(wavelength: 880nm, 6.
Chapter4 External Interfaces Note Please hold the air plug to remove the NIBP cuff. ①Cuff Socket Left side The right side of the device is USB socket and AC adapter socket USB socket AC adapter socket Right side Note The cuff socket and AC adapter socket of the sphygmomanometer only connect to the stated equipment which accord with the requirements of IEC 60601-1: 1988 “Medical electrical equipment-Part 1: General requirements for safety”.
Chapter5 Dry Battery/AC Adapter Installation This product can use dry batteries as well as AC adapter. ① ② ③ 5.1 Dry Battery Installation ① Demount the battery cover in the direction of the arrow. ② Install "AA" dry batteries according to ③ Slide to close the battery cover. Icon “ ” polarities. : the batteries power will exhaust. Replace with four new batteries (the same sort) at the same time. Test while low power may cause data deviation and other problems.
battery power will not be consumed. Switch regulated power supply and dry batteries when the device is off, otherwise, the device may shutdown due to power failure.
Chapter6 Button Functions All the operations to the Electronic Sphygmomanometer are through buttons. The names of the buttons are above them. They are: 【 ON/OFF】 ON/OFF button. press it to turn on/off the device. 【 START/STOP 】 Press to inflate the cuff and start a blood pressure measurement. When measuring, press to cancel the measurement and deflate the cuff. Long press this button can connect the network fleetly .
Chapter7 Set Date and Time It is necessary to set date and time after power on. The Electronic Sphygmomanometer can automatically stores measurement results with date and time If dry batteries power exhausts or removed, the time to stop. At the moment, please reset date and time. Short-term(less than 5 minutes) power cut does not affect time.(such as replacing batteries) The Electronic Sphygmomanometer stores 100 groups of measurement results at most.
(3)When the Sphygmomanometer is ON, users manually search and connect it through mobile phone software, the time of the Sphygmomanometer will be synchronized. 2. After setting, select 【CONFIRM】 option and press 【ENTER】 button to confirm the setting value. If you do not want to change the time, select 【EXIT】 option and press 【ENTER】 button to return to the previous menu.
Chapter8 Unit and Language 8.1 Measurement Unit There are two units: "mmHg" and "kPa". The default is "mmHg". Enter 【SYSTEM SETUP】 submenu in 【MENU】, then select 【UNIT】 option to switch units between "mmHg" and "kPa". 8.2 Language The sphygmomanometer supports both English and Chinese, the default is Chinese, enter 【SYSTEM SETUP】 submenu in 【MENU】 and select 【LANGUAGE】 can switch languages.
Chapter9 Alarm Function Alarms are classified into two categories: technical alarm and physiological alarm. 9.1 Physiological Alarm User can press 【MENU】 button to enter system menu, select 【ALARM SETUP】 option to enter its interface, and then set alarm on-off and the high and low alarm limits, during setting alarm parameter, if the high limit lower than the low limit, the device will display a prompt, users allow or reset it according to the actual situation.
Chapter10 Measurement Mode The sphygmomanometer can be set to neonate, pediatrics and adult three modes. Press 【MENU】button to enter 【SYSTEM SETUP】 interface, then users can set different modes through 【USER TYPE】 option.
Chapter11 Application of the Sphygmomanometer 11.1 Accurate Measurement Way Measurement in quiet and relaxing state. 1.Place your elbow on a table. 2.The cuff is level with your heart. 3.The palm of the hand is up, and the body relax. Try to measure your blood pressure at the same time each day with the same arm and the same pose for consistency. The high and low location of cuff will cause changes in measurement results. Do not touch Electronic Sphygmomanometer, cuff and windpipe during measurement.
② Stretch cuff into a barrel for the arm can conformable enter into the barrel. ③ Left arm penetrate through the cuff, the air tube of the cuff will pass the top of your palm. ④ Wrap the cuff to your upper arm. Make the air tube inside the forearm and aligned with your middle finger. ⑤ The bottom of the cuff should be approximately 2cm~3cm above your elbow. ⑥ Be fixed with cloths, and wrapped tight cuff, the arm and the cuff should not have gaps. 11.
During measurement, please keep correct pose and quiet state, do not move. Wish to stop measurement During measurement, press 【START/STOP】 button, stop press,release the air from the cuff. 错误!未找到引用源。Confirm the Measurement Value The measurement value can be stored automatically, using [memory function] (refer to Chapter12). *Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician. Note Wait 4-5 minutes between measurements.
Chapter12 Memory Fuction The devicer is designed to store and display the blood pressure, pulse rate values and the date and time when measured, which are up to 100 groups. If there have been stored 100 groups, the earliest results will be deleted when saving the 101 group of measurement results. 12.1 Read Memory Values 1. In the main interface (interface when boot-strap), press 【MEMORY】 button to review the most recent measurement values in large-print, press 【LIST】 button to enter data list interface.
Finish displaying the measurement values. Press 【EXIT】 button to return to the main interface or long press 【ON/OFF】 button to turn the power off. *The device will automatically turn off after 1 minute in which there is no operation to the device and no connection with SpO2 probe, even if you forget to turn the power off. 12.2 Delete Memory Values Users can delete all memory values of users instead of separately delete the special item. 1.
Chapter13 Bluetooth Data Sending The sphygmomanometer can send the storage BP value to PC through bluetooth.(refer to software help for details) Users connect the sphygmomanometer to PC after searching it on PC client, after completing the connection, data will transmit to PC through bluetooth. After the sphygmomanometer finished data transmission, it will mark in the measurement review interface.
Chapter14 SpO2 Measurement Function Precaution for SpO2 measurement Warning ◎Pulse oximeter can overestimate the SpO2 value in the presence of Hb-CO, Met-Hb or dye dilution chemicals. ◎ES (Electrosurgery) equipment wire and SpO2 cable must not be tangled up. ◎Do not put the sensor on extremities with arterial catheter or venous syringe.
the microcirculation barrier patients. It is recommended that the sensor should not be applied to the same finger for over 2 hours. ◎Prolonged and continuous monitoring may increase jeopardy of unexpected change of dermal condition such as abnormal sensitivity, erubescence, vesicle, repressive putrescence, Particularly in newborns or in a Perfusion disorders and changes or immature skin form of the patient.
Chapter15 SpO2 Measurement Method 1. Attach the sensor to the appropriate site of the patient finger as following figure. Place SpO2 probe 2. Plug the connector of the SpO2 probe cable into the USB socket in the lower right of the device. The main interface will switch to SpO2 interface. This operation brings no affection to other functions.
Chapter16 Maintenance, Cleaning and Keeping *Please follow the instructions in the user manual. If you do not comply, our company will not assume responsibilities of the quality. Warning Must remove batteries and cut off the alternating power supply before cleaning the sphygmomanometer, accessories must be clean separately. Caution Do not high pressure disinfect the sphygmomanometer and accessories. Do not immerse the sphygmomanometer and accessories into any liquid.
Keeping: Advice Do not place the device in the following areas: Easy to splash water areas. Direct sunlight, extreme hot, humidity, dust, causticity gas areas. Lean or the area which can cause vibration, impact. Chemicals or corrosive gas storage areas. Remove the batteries if the device will not be used for long time. Note The service life of the device is five years.
Chapter17 Error Message Error message will be displayed in the screen if there is something wrong when measuring.
Chapter18 Troubleshooting Abnormal Phenomenons BP measurement values too high or too low No pressure Cuff deflates in short time Causes Solutions Cuff is not connected correctly Correctly connect cuff(refer to chapter11) Talk or move arms when measuring Keep quiet and restart a measurement The turnup clothing presses the arm Take off the clothing which presses the arm, and restart a measurement Cuff leakage Buy a new cuff The cuff windpipe is not correctly connected with cuff Correctly conne
Chapter19 Meanings of Symbols Symbol Description Warning – refer to User Manual Refer to the accompanying document(the User Manual) SYS Systolic pressure MAP Mean pressure DIA Diastolic pressure PR Pulse rate (bpm) ADU Adult INFO Information The alarm is ON The alarm is OFF Low-power Full-power 1.no finger inserted to SpO2 probe 2.
Chapter20 Specification Name The Electronic Sphygmomanometer degree protection of against ingress of liquid Display mode Ordinary sealing device, without the function of preventing liquid from entering 2.8"color LCD Display NIBP Specifications Measurement Method Oscillometric method Working mode Manual operation Measurement Range Pressure adult 0~290mmHg(0~38.6kPa) pediatric 0~235mmHg(0~31.3kPa) neonatal 0~140mmHg(0~18.
Safety classification class Ⅱ, type BF applied equipment The service life of the device is five years or 10000 times of BP Service life measurement. FCC Cautions: 1) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.