Specifications
> 7 <
Battery back-up
D
ial / minimum
switching time
Rated voltage
F
requency
Switching capacity
Contact
Maxim. recommended load
Incandescent
Fluorescent
Low voltage halogen
Halogen (230 Va.c.)
Low consumption lamps
LED
Operating temperature
Installation
Protection type
Connection diagram
Dimensions
QRD / QRDD / QRSD: 100 hours minimum
O
ther models without battery back-up on request.
Q
RD: Daily-15 min. QRDD: 2Daily-15 min. / 30 min.
QRSD: Weekly-2 hours / Daily-30 min.
120 or 230 Va.c.
12, 24 or 48 Va.c. / d.c.
5
0 / 60 Hz
QRD:
16(4) A / 250 V;
QRDD and
QRSD: 2x16(4) A / 250 Va.c.
QRD: 1 Changeover
QRDD and QRSD: 2 Changeovers
3000 W
500 W
2250 VA
3000 W
500 W
-
-10ºC to +50ºC
Surface - Panel mounting
(Faston connexions) DIN rail
IP 20
D / S: No reserve
Q
RD / QRS: 100 hours minimum
D
: Daily / 15 min. S: Weekly / 2 hours
QRD: Daily / 15 min.
QRS:
Weekly / 2 hours
D / S: 120 or 230 Va.c.
QRD/QRS: 120 or 230 Va.c. 6, 12, 24 or 48 Va.c. / d.c.
D
/ S: 50 or 60 Hz
QRD and QRS: 45/60 Hz
16 (4) A / 250 Va.c.
Changeover
2000 W
1200 W
2000 VA
2000 W
900 W
1000W
-10ºC to +50ºC
Surface - Flush mounting
(Faston connexions) DIN rail
IP 20
D: No reserve
Q
RD and QRS: 100 hours minimum
D
: Daily /15 min.
QRS: Weekly / 2 hours
D: 120 or 230 Va.c.
QRD/QRS: 120 or 230 Va.c. 6, 12, 24 or 48 Va.c. / d.c.
D
: 50 or 60 Hz
QRD and QRS: 50/60 Hz
16 (4) A / 250 Va.c.
Changeover
3000 W
1200 W
2000 VA
3000 W
900 W
1000 W
D: 0ºC to +55ºC; QRD / QRS: -10ºC to +45ºC
MINI: DIN rail - Surface (sealable terminals).
MINI T: DIN rail - Surface - Flush mounting (Faston connex.).
IP 20
CRONO ALPHA MINI / MINI T
48
100
69
69
O
A
I
6
12
9
3
57
72
94
72
73.5
72
104
72
> Features
>
ANALOG TIME SWITCHES
Check for other models
DAILY DAILY
> Description
Analog time switches to timer circuits such as illumination, acclimatization, pumps, etc. DIN rail, Surface or
Panel mounting.
Weight: 280/313 gr. Weight: 202/216 gr. Weight: 199/206 gr.
MINI T :
Flush mounting
. Front 72 x 72 mm