REMOTE MANAGEMENT SYSTEMS FOR ELECTRICAL BOARDS
The master module, designated ORBICOM, is an autonomous element that is ins-
talled on the lighting board and which performs the following functions:
It measures the line voltage in true r.m.s. value between each phase and neutral,
reaches 255 V.
• It measures the active power in each of the three phases.
Maximum current: 80 A per phase.
It will calculate the cos φ for each of the three phases.
It will calculate the active power in each of the three phases, between each phase
and neutral.
It will calculate the total active power.
It incorporates configurable astronomical switch on and switch off operations.
It will measure the voltage in true r.m.s. value between each phase and neutral at
the lighting line outputs, when installed with ESDONI equipment, reaches 255 V.
It calculates the savings for each phase in %, when installed with ESDONI equip-
ment.
It calculates the total savings in % when installed with ESDONI equipment.
Intruder, wiring theft and blown lamp alarms.
Connection for up to 15 NODITEL units per RS-485 port.
Direct event reading on the equipment display.
Remote data transmission to a central unit over RS-232 modem, via GSM
modem, telephone wires etc.
Remote programming of switch on and switch off in astronomical or fixed mode.
Reduc on/off voluntario: ON/OFF Voluntary reduction. The nodes designated NODI-
TEL are elements that are supplementary to the ORBICOM that enable system func-
tions to be to be expanded, acquiring data and transmitting them to the master.
Their most important specifications and functions are:
Nodes that communicate with the ORBICOM via RS-485.
Detection of fuse, breaker earth-leakage breaker failures etc.
(by detecting voltages of less than 160V R.M.S.).
Each NODITEL includes DIP switches for address programming.
The RS-485 can connect to a maximum of 15 NODITEL slaves.
Direct power supply connection to the 230 V grid.
When power is applied to the module, the green LED is switched on indicating
power is present. If there are no problems, the Green LED will flash at a rate of
0.5 seconds ON/1 second-OFF.
If the unit detects a problem, for example, a missing or low (less than
160 V) phase, the red LED ROJO will flash at a higher rate (0.1 seconds Ton
and 0.1 seconds Toff).
Each module can detect the voltage in up to three phases in the same line, which
is R, S and T with its neutral, or between phase and neutral in single-phase lines.
> 5 1 <
ORBICOM NODITEL
> Features
Rated line voltage
Measured voltage
Maximum current per phase
Frequency
Own consumption
Battery back up
Operational precision
Operating temperature
Precision accuracy class
Protection class
Protection type
Mechanical strength
Installation
3 x 230/400 Va.c.
3 x 230 Va.c. + N
80 A
50 Hz
Approx. 20 VA
6 years using a lithium battery
< ±0, 5 s/24 h at 23 ºC
-10 ºC to + 45 ºC
Class 1 active power - Class 2 reactive power
II adequate mounting
IP 51
IK 06
Fastening triangle in surface according to DIN 43857
> Features
Rated line voltage
Measured voltage
Alarm voltage per phase
Frequency
Own consumption
Operating temperature
Precision class
Protection class
Protection type
Mechanical strength
Installation
230 Va.c.
3 x 230 Va.c. + N
160 Va.c.
50 Hz
Approx. 5 VA
-10 ºC to + 45 ºC
Class 1
II adequate mounting
IP 20
IK 02
On the top of the symmetrical profile measu-
ring 35mm using EN60715. DIN Rail.
> Dimensions > Dimensions> Connection diagram
SYS ON
SMS
ASTRONOMIC
REDUC
ON-OFF
VOLUNTARY
BY - PASS
Weight: 2777 gr. Weight: 223 gr.