Specifications
> 3 7 <
Rated voltage
Battery substitution time
S
witching capacity
Contact
B
attery life
Minimum programmable time
Temperature accuracy
Resolution
Temp. measurement period
Output relay updating
Programming type
Temperature range
Operating temperature
Protection class
Protection type
Installation
Accessories
Connection diagram
Dimensions
2 alkaline batteries 1, 5 V AAA (LR03)
10 minutes
5
(1) A 250 Va.c.
Changeover
1
year approximately
30 min.
± 0, 5 ºC
0, 1 ºC
30 seconds
1 minute
Weekly with 8 daily programs/ 2 temperatures +
anti ice
0 ºC to 50 ºC (internal probe)
-10 ºC to +50 ºC (external probe)
0 ºC to 50 ºC
II according to EN 60335 under correct assembly
conditions
IP 40
Surface or over mechanism box
X.TEMP RF and RF system plug-in signal repeater
2 alkaline batteries 1, 5 V AAA (LR03)
2 minutes
8
A / 250 Va.c.
Changeover
1
year approximately
30 min.
± 0, 5 ºC
0, 1º C
30 seconds
-
Weekly with 7 daily programs/ 4 temperatures
2 ºC to 35 ºC approx.
-40ºC to 60ºC (with external probe)
0 ºC to 50 ºC approx.
II according to EN 60335 under correct assembly
conditions
IP 40
Surface or over mechanism box
X CODE GSM, X CODE WAVE, MA 16,
X TEMP 100K, TX ATHENA, ATHENA TEMP,
RX1 8A, RX4 8A, RX.ANT
> Features
>
CRONOTHERMOSTATS
> Description
A
THENA enables the acclimatization control for up to
f
our different areas by means of extra probes (ATHE-
NA TEMP) connected by BUS cable. It can be con-
nected without cables (TX ATHENA) with the actua-
t
or RX4 8A; admits phone controller (X.CODE WAVE
o
r X.CODE GSM).
T
he NEO
R
F
k
it is the easiest way to control the accli-
m
atization by means of a wireless solution. It is
made up of a plug in actuator for the heater, a
NEO
RF
cronothermostat and an optional external
p
robe.
NEO
RF
EXTERNAL
PROBE
E
XTERNAL PROBE
(optional)
HEATER
HEATER ACTUATOR
Thermostat –
heater connection
T
HERMO X is a weekly electronic cronothermostat
w
ich combines simplicity of use with functional
innovation, making it an excellent domestic tempe-
rature regulators.
NEO
RF
/
KIT CLIMATIZACIÓN
ATHENATHERMO X
2 alkaline batteries 1,5 V AA (LR06)
-
8
A / 250 Va.c.
Changeover
2
years approximately
1 hour
± 0,5 ºC
0,1 ºC
-
-
Weekly with 7 programs / 3 temperatures
2 ºC to 35 ºC (heating automatic/manual)
10 ºC to 35 ºC (air conditioning automatic/manual)
-40ºC to 60ºC (with external probe)
0 ºC to 50 ºC
II according to EN 60335 under correct assembly
conditions
IP 40
Surface or over mechanism box
X.CODE WAVE, X.CODE GSM, MA 16,
X.TEMP 100K.
Weight: 309 gr. Weight: 426 gr. Weight: 493 gr.
HEATER ACTUATOR /
REPETITOR