Specifications
> 2 4 <
R
ated Voltage
F
requency
Switching capacity
Own consumption
Sensitivity
Operating temperature
Protection Class
Protection type
Installation
Accessories
Connection diagram
Dimensions
2
30 Va.c.
5
0 - 60 Hz
6(2) A 250 Va.c.
3, 5 VA
50 kW maximum
-10ºC to +45ºC
II according to EN 60335 under correct
assembly conditions
IP 20
DIN rail
Optional: 3 probe set
2
30 Va.c. or 400 Va.c
5
0 - 60 Hz
8 (2) A 230 Va.c. / 4 (1) A 400 Va.c.
4 VA
From 0 to 50 kW
-10ºC to +45ºC
II according to EN 60335 under correct
assembly conditions
IP 20
DIN rail
Optional: 6 probes set
2
30 Va.c.
Voltage control: 5 V-230 Vd.c. programmable
-
16 A / 230 Va.c. ~ cos j = 1
0, 8 W
5 mA-200 mA
-10ºC to +45ºC
II according to EN 60335 under correct
assembly conditions
IP 20
DIN rail
GLE 12-3: Special load accessory
EBR-1 EBR-2 FR12-1
82
45
59
17.5
45
65.5
86
71
> Features
>
LEVEL CONTROL RELAY/ PHASE DISCONNECTOR
> D
escription
They are designed for controlling the filling and emptying of water wells
and tanks by means of probes
The mains disconnection switch
disconnects the power supply
once all series connected loads
are turned off, thus preventing any
electromagnetic interference fields
from occurring.
FILLING
FILLING
EMPTYING
EMPTYING
Weight: 184 gr. Weight: 333 gr. Weight: 73 gr.