Specifications

> 2 2 <
Angle
D
etection field
Rated voltage
Switching capacity
Maximum recommended load
Incandescent
Compensated fluorescent
Low voltage halogen
Halogen (230 Va.c.)
Low consumption lamps
Downlight lamps
LED
Adjustable parameters
Temporization
Light sensitivity
Operating temperature
Protection type
Connection diagram
Dimensions
360º
Up to 7 m diameter to 2, 5 m height
230 Va.c. / 50 Hz
DICROMAT +:
10 A / 230 Va.c. ~
j = 1
D
ICROMAT 2+
:
2
x 10 A / 230 Va.c. ~
j =
1
2200 W
400 W
1000 VA
2200 W
400 W
By means of contactor
-
Time (T1 and T2), light sensitivity (T1)
and field of detection (T1 and T2)
DICROMAT +: T
1
: from 1 s to 10 min.
DICROMAT 2+: T
1
: from 1 s to 10 min.
T
2
: from 10 s to 15 min.
2 - 2000 lux.
-10ºC to +45ºC
IP 20
360º
U
p to 7 m diameter to 2, 5 m height
230 Va.c. / 50 Hz
T1: 10 A / 230 Va.c. ~ cos j = 1
T
2: 5 A / 250 Va.c. ~ cos
j =
1
T
1
:
2000 W
By means of contactor
300 VA
1000 W
By means of contactor
By means of contactor
-
Time (T1 and T2) and light sensitivity
(T1)
DICROMAT MINI:
T
1
: from 6 s to 12 min.
DICROMAT 2 MINI:
T
1
:
from 6 s to 12 min.
T
2
: from 10 s to 30 min.
Adjustable from 5 Lux. to
-10ºC to +45ºC
IP 20
360º
U
p to 4 m diameter to 2, 5 m height
230 Va.c. / 50 Hz
10 A / 230 Va.c. ~ cos j = 1
2000 W
By means of contactor
300 VA
1000 W
By means of contactor
By means of contactor
-
Time and light sensitivity
T
1
: from 6 s to 12 min.
Adjustable from 5 Lux. Up to
-10ºC to +45ºC
IP 20
> Features
>
MOVEMENT SENSOR SWITCHES
> Description
Presence switches for the automatizing of light circuits in buildings, hotels, residen-
ces, offices, etc. Mounted built in on the ceiling.
DICROMAT + / DICROMAT 2+
DICROMAT SENSOR +
DICROMAT MINI
DICROMAT 2 MINI
DICROMAT MICRO
DICROMAT + CR
DICROMAT 2+ CR
153.5
33.550
¯20 ¯16
30
24.5
153.5
33.550
39.5
¯54
¯65
DICROMAT + /
DICROMAT + CR
:
Enables to add up to 4 DICROMAT SENSOR +
360º
Up to 7 m diameter to 2, 5 m height
230 Va.c. / 50 Hz
DICROMAT + CR: 10 A / 230 V cos j = 1
D
ICROMAT 2+ CR: 2x10 A / 230 V cos
j =
1
2200 W
1200 W
2000 VA
2200 W
1000 W
900 W
1000 W
Time (T1 and T2),
light sensitivity (T1) and field of
detection (T1 and T2)
DICROMAT +CR: T
1
:
from 1 s to 10 min.
DICROMAT 2+CR: T
1
:
from 1 s to 10 min.
T
2
:
from 10 s to 15 min.
2 - 2000 lux.
-10ºC to +45ºC
IP 20
Connection diagram
Dimensions
D
ICROMAT+
N
L
L
N
L
N
N
L
L
L
N
N
T
2
T
1
D
ICROMAT 2+
DICROMAT 2+ /
DICROMAT 2+ CR:
Enables to add up to 14 DICROMAT SENSOR +
Weight: 193 gr.
Weight :
Consult/255 gr.
Weight : 317/449/293 gr.
Weight : 277/Consult/62 gr.
Manual programming or
with remote control RC of
the adjustable parameters in
RC proximity detectors.